DVP-NS50P/NS41P/NS52P
SECTION 6
TEST MODE
6-1. EXECUTING IOP MEASUREMENT(5)Wait until a hexadecimal number appear.
Manual Adjust
In order to execute IOP measurement, the following standard
procedures must be followed.
1. Track Balance Adjust:
2. Track Gain Adjust:
(1)In standby mode, press [TOP MENU], [CLEAR],
3. Focus Balance Adjust:
[POWER] to enter Remocon Diagnosis Mode.4. Focus Gain Adjust:
5. Eq Boost Adjust:
Remocon Diagnosis Menu6. Iop. ED:
7. TRV. Level:
0. External Chip Check8. S curve(FE) Level:
1. Servo Parameter Check9. RFL(PI) Level:
2. Drive Manual Operation0. MIRR Time:
3. Emergency History Check
4. Version information$4 Change Value
5. Video Level Adjustment[RETURN] Return to previous menu
Model: xxx xxx xxx
IF-con Ver : xxx(6)Convert data from hexadecimal to decimal.
Syscon Ver : xxx
(7)Use the following formula to calculate IOP in mA
IOP (mA)=IOP (decimal) x 0.622678.
(2)Select ?2. Drive Manual Operation? by pressing the 2
key on the remote commander. The screen will appear as
(8)Press [RETURN] to return back to previous menu.
below.
Drive Manual Operation(9)Press - to return to Top Menu and power OFF the DVD
Player.
1. Servo Control
2. Track/Layer Jump6-2. EMERGENCY HISTORY CHECK
3. Manual Adjustment
4. Mecha Test Mode
0. Return to top MenuInformation of Emergency History.
(1)In standby mode, press [TOP MENU], [CLEAR],
[POWER] to enter Remocon Diagnosis Mode.
(3)Select ?3. Manual Adjustment? by pressing the 3 key on
the remote commander. The screen will appear as below.
(2)Select ?3. Emergency History?.
Manual Adjust
Emg. History Check
1. Track Balance Adjust:
2. Track Gain Adjust:Laser HoursCD999h 59min
3. Focus Balance Adjust:DVD999h 59min
4. Focus Gain Adjust:
5. Eg boost Adjust:1. 01 05 04 0400 92 46 00
6. Iop:00 00 00 0000 00 23 45
7. TRV. Level:
8. S curve(FE) Level:2. 02 02 01 0100 A9 4B 00
9. RFL(PI) Level:00 00 00 0000 00 23 45
0. MIRR Time:
[Next] Next Page [Prev] Prev Page
$4 Change Value
[RETURN] Return to previous menu
(3)Laser Hours
DVD Laser ON time. (Total ON time)
(4)Select Iop by pressing 6 key on the remote commander.CD Laser ON time. (Total ON time)
(4)Emergency History
The history information from last ?1? to ?10? can be
scrolled with [NEXT] key or [PREV] key.
(5)Error code
Example of Error code
1. 01 05 04 0400 92 46 00
00 00 00 0000 00 23 45
6-1 |