CONVERSIONS
Warning:figure 22).
Conversion of this appliance shall only be- Unscrew the injector with the open ended spanner
carried out only by authorised personnel.until there is clearance for the spring hook ?P?, to
engage the injector.
11) REPLACEMENT OF INJECTORS- Unscrew the injector completely.
The burners are suitable for use with different gases.
Re-installation of injectors
To adjust to different gases it is necessary to change
- Select the correct injector.
the injectors.
- Hold injector with spring and offer it to the control
A range of injectors are supplied with the appliance.
valve.
PROCEDURES
- Use spanner ?M?, to engage the threads.
Removal of injectors
- Remove spring ?P?.
- Remove control panel (refer section 9).
- Tighten injector with ring spanner ?M?.
- Loosen screw ?A? and slide sleeve ?B?, away from
The technical details of the operating pressures,
control valve (refer figure 21).
injector diameters and rating for various gases are
- Loosen the injector with the ring spanner ?M? (refer
scheduled below.
BURNER ARRANGEMENT ON THE HOB
TABLE
OPERATING PRIMARY AIRDIAMETERHEAT
BURNERS
CLEARANCE ?S?INJECTORSINPUT
PRESSUREGAS
(FIG. 19)
kPa1/00 mm
N°DESCRIPTIONmmMJ/hW
LARGEPropane2.759.009011.23100
1
LEFT FRONTNatural1.009.0015011.23100
MEDIUMPropane2.759.009010.22950
2
RIGHT REARNatural1.009.0014510.22950
SMALLPropane2.759.00604.91450
3
LEFT REARNatural1.009.001004.91450
AUXILIARYPropane2.751.00504.01050
4
RIGHT FRONTNatural1.009.00904.01050
FISH BURNERPropane2.759.00839.22600
5
CENTERNatural1.009.001369.22600
WOK BURNERPropane2.75complete10214.04000
6
LEFT FRONTNatural1.00complete17014.04000
FIG. 21FIG. 22
9 |