Description of the hobElectrical connection
WARNING: THIS APPLIANCE MUST BE EARTHED.
2it must be cut off and disposed of properly. To avoid
the risk of electrocution, the moulded plug must not
61.HobCOPPER PIPE OR
appliance. Three pin plugs to BS1363 with a capacitySTAINLESS STEEL HOSE
YES
2.Medium semi-rapid burnerof not less than 13A must be used and fitted with a
4
3 amp fuse �ASTAO approved to BS 1362.
3.Small auxiliary burner
With moulded plugs, after replacing the fuse the
BAND
4.Large rapid burnerobtained from your supplier. The colour of the correctCLAMPS
fuse cover is that of the coloured insert in the base
5.Burner control knobs
3fuse cover. If you wish to make a direct connection
6.Triple flame burnerto the mains, an omnipolar switch with a gap betweenService
5opening in
cabinet
1
2REAR VIEW
Instructions for use
Once the hob has been installed, it is important to remove any protectiveNO
materials, which were put on in the factory.
The hob control knobs
The symbols on the control knobs mean the following:
no gas flow
REAR VIEW
maximum gas flow
minimum gas flow
Important
The wires in the mains lead are coloured in accordance with the following code:
All operating positions must be set between the maximum and minimum flow settings,
GREEN AND YELLOW ........EARTH
BLUE ....................................NEUTRAL
BROWN ...............................LIVE
DThe wires should be connected into the terminal of your plug as follows:
Fig. 1
AEARTH: to the terminal marked E, or coloured GREEN or GREEN / YELLOW.
NEUTRAL: to the terminal marked N, or coloured BLACK or BLUE.
A
LIVE: to the terminal marked L, or coloured RED or BROWN.
A-Burner cap
green and yellow
Plug in the appliance. Turn on the electricity supply.
B-Lighting plug(earth)
C- Thermocouple
3A
CCD-Triple flame cap
Bfuse
B(3amp)
blue (neutral)brown (live)