USE
Control panel
S1
S2
S3
0 - 1
0 - 1T1 T2
T3
S4reset
S5
R
15
3060
Ldelay
reset
V1
V2
V3
V4
V5
T
LLightSwitches the lighting system on and off.
S1 LedMotor running led.
S2 LedOptimum speed led.
S3 LedIntensive speed led.
S4 LedGrease filters saturated alarm led.
S5 LedActivated charcoal filter exhausted alarm led.
To disable this indicator (Ducted hoods) simultaneously press buttons R (using
a sharp object, for example a pencil) and V2. To enable it again, press buttons R
and V3.
RResetInternal Filter Alarms Reset button.
V1 MotorSwitches the extractor motor on and off.
V2 SpeedDecreases the operating speed.
V3 SpeedIncreases the operating speed.
V4 Optimum Preset optimum speed. To customise the Optimum speed setting, select the Speed
speedyou require using buttons V2 and V3 then press V4 within 10 seconds (during
this period the corresponding led S2 will flash). The setting you enter will remain
active until the Hood is turned off.
V5 IntensiveMaximum speed, used to eliminate the highest levels of cooking vapour
speedemission. Returns to Optimum speed automatically after it has been in operation
for 15 minutes. Intensive speed can also be turned off manually by pressing
button V4.
TDelayedThis device allows any residual odours to be removed without having to wait
shutdown and turn the appliance off, as the Motor and Lighting will switch off automatically
at the end of the selected time.
By pressing button T in succession it is possible to set the delayed shutdown of
the appliance to 15, 30 and 60 minutes, respectively. The selected time is shown
by leds T1, T2, T3. To move from one time to another, simply press button T
until the required led lights up. The time selected in this way will start from
zero. The delayed shutdown function can be turned ofV4.f by pressing button
T1 Led15O delayed shutdown indicator led.
T2 Led30O delayed shutdown indicator led.
T3 Led60O delayed shutdown indicator led.
GB18 |