2. Status Indicators
ViewŢnder Indicators: END blinking: Film end coming up in X feet/meters (OX� can bet set by user)
END glows: Camera ran out of Ţlm
ASY:Asynchronous operation; camera is not running at set fps rate
BAT:Low battery (less than 20 volts). Exchange battery.
Display Indicators:TC glows:Timecode exposure is enabled and timecode is set
TC blinks:Timecode exposure is enabled, but not recording properly
bat:Low battery (less than 20 volts). Exchange battery.
asy:Asynchronous operation; camera is not running at set fps rate
end �ashesFilm end coming up in X feet/meters (OX� can be set by user)
end glows:Camera ran out of Ţlm
fps �ashes:ESU is not receiving a valid signal
PROG glows: Internal program is activated
Display Warnings:The LCD Display will indicate any situations that will prevent running the
camera by changing one or more of its digits into underlines.
MagazineMagazineMagazine
improperly attachednot readycommunications check
ft
0 0 0 0
fps
_ 0 0 0
Movement block Film jam in Sprocket guides Film jam in lower
not lockedupper loop areaare openloop area, or Ţlm end
Arri�ex 535B Quick Guide, 4/99, Page 6 |