2016-2
DIVE TIME MEASUREMENT MODESITE MODE
The Dive Time Measurement Mode lets youMode indicatorThe Site Mode lets you view the current time in
Current time
measure the total time you spend underwaterany one of 10 different sites. Your watch comesSite name
while diving or snorkeling, and the amount ofpre-programmed with site data (site name and
Mode indicator
time spent on the surface (surface interval). TheGMT differential) for famous snorkeling and
watch also stores one set of diving time datadiving sites around the world. You can use this
AB(total dive time and dive start time) into logABsite data as it is or change it to suit your needs.
Pmemory for later recall.
P
Viewing the Time in Another Site
P
In the Site Mode, press C to scroll forward
M DIVECTIMEWarning!MC
For your own safety, never operate thethrough the site data.
Dive timebuttons of the watch while underwater or
Current time in theChanging Site Data
while on the waterOs surface. Perform button
selected siteSite data consists of the site name, DST setting,
operations in a safe place after leaving the
Current timeand the GMT differential of the site. Changing
water.
site data causes its time to be set automatically
in accordance with the GMT differential.
Before Diving/Snorkeling
? Be sure to check if the battery power is low (check for low light? You cannot change the site data of the site that is set as your Home Site
intensity, a dim display, or the flashing indicator). If it is, do notin the Timekeeping Mode.
use the watch for diving/snorkeling.
To change site data
? Make sure that the watch is set to the correct time.
1. In the Site Mode, use C to display the name
? Check the glass, case and band for cracks or chips.Cursor
of the site whose data you want to change.
? Make sure that the band is fastened securely around your wrist.
2. Hold down A until the cursor appears on the
AB
While Diving/Snorkelingdisplay.
? Always use the Obuddy system� when diving � never dive alone.P? If your Home Site is on the display, pressing
? Check to make sure that timer operation is being performed properly.PA causes the indicator HOME to appear,
? Take care when diving/snorkeling near rocks or coral to avoidMCwithout the cursor.
scratching the watch.3. Use M to move the cursor to the location of
the site name character you want to change.
After Diving/Snorkeling
To avoid corrosion, rinse your watch thoroughly with fresh water to4. Use B and C to scroll through characters at the cursor position. Each
remove salt water, dirt, etc. When possible, soak the watch in freshpress of these buttons scrolls through characters in the sequence shown
water overnight to make sure that all salt is removed.below.
Press C.Press B.
Using the Dive Time Measurement Mode(space)A to Z1 to 0-
1. Before diving/snorkeling, switch to the Dive
Dive start time
Time Measurement Mode by holding down
)(/.
Current timeM for at least one second.
2. To start the dive time measurement operation,5. Repeat steps 3 and 4 to input all the characters of the site name.
press C.
APB? To delete a character, input a space.
3. To stop the measurement, hold down C for
? A site name can be up to 14 characters long.
Pat least one second (until the watch emits a
long beep).6. After you input the site name, press M until
M DIVETIMEC4. To re-start timing from the dive time shownABthe current DST/Standard Time setting starts
on the display, press C.flashing on the display.
? You can repeat steps 3 and 4 as manyGMT?O indicates DST and OFF indicates
Dive time
Standard Time.
(hours : minutes seconds)times as you like.
5. To clear the Dive Time Measurement Mode,MC? The site name area has spaces for 14
stop the measurement operation (step 3,characters, so you must continue to press
above) and then press A.GMT differentialM until you get past the 14th character.
7. Press C to toggle between DST (O ) and
NotesStandard Time OFF( ).
? Timing of the surface interval starts whenever you hold down C to stop
the dive time measurement operation in step 3, above. This timing is8. Press M and the current GMT differential starts to flash.
performed internally, and it is not indicated on the Dive Time Measurement9. Press C to increase the setting or B to decrease it.
Mode screen. For details on how to view surface interval data, see? See OTIME ZONE TABLE� for GMT differential information for a number
OViewing Log Data�.of time zones and cities.
? Do not recall log data while a dive time measurement is stopped10.Press A to return to the Site Time screen.
and you plan to re-start it. If you do, the dive time to that point will be
stored into memory and the data will be cleared when you exit the DiveSwitching a Site Time between DST and Standard Time
Time Measurement Mode.1. In the Site Mode, display the name of the site whose DST/Standard
Time setting you want to change.
2. Hold down A until the cursor appears on the display.
Viewing Log Data
3. Press M 14 times until the DST/Standard Time setting screen appears,
1. Hold down M for at least one second to enter
Dive start timewith either O or OFF flashing.
the Timekeeping Mode from the Dive Time
4. Press C to toggle the setting between DSTO ) and Standard (Time
Surface intervalMeasurement Mode.
(hours : minutes)2.Hold down C to display the Log Data screen.(OFF).
5. Press A to return to the Site Time screen.
The Log Data screen remains visible as long
INTERVAL
ABas you hold down C. When you release C,
the normal Timekeeping Mode screen
P
returns.
? The surface interval continues to be timedIDENTIFICATION MODE
MLOG DIVETIMECuntil you re-start dive time measurement
or until the surface interval reaches 24Mode indicatorWith the Identification (ID) Mode, you can store
Dive time
hours.your name, SCUBA diver certificate number,Title
emergency contact number, passport number,
Text area
and blood type.
Clearing the Log Data Memory
Log data in memory is automatically replacedABAbout Identification Mode Data
INTERVALby the newest measurement. Use the following
AB? The Identification Mode has five pre-
operation if you want to manually clear the logprogrammed data titles: NAME (name),
data memory.C CARD (SCUBA diver certificate number),
MC
1. While in the Timekeeping Mode, hold downEMERGENCY NO. (emergency contact
MLOG DIVETIMECnumber), PASSPORT (passport number),
C to display the Log Data screen.
2. While holding down C, press A to clear theand BLOOD TYPE (blood type).Number area
log data memory.? Except for BLOOD TYPE, you can input
? At this time, the display clears so that no16 characters (letters, numbers, symbols) in
data is shown.the text area and 10 digits in the number area. |