Alarm Recording Operation
1Check that a video cassette with its tab intact has 4Press the shift ( ) button to move the flashing to
been inserted.DURATION.
Press the set (+ or -) button to set the recording
2Set the MENU/REC LOCK switch to MENU to duration.
display the menu screens. Press the page button
to display the alarm recording setting screen (Menu 5Upon completion of the settings, set the MENU/
Screen 3) on the TV monitor.REC LOCK switch to OFF. The regular screen is
restored.
[ALARM] P3
MODE : OFFIf an alarm input signal is subsequently supplied,
DURATION : 30SECthe time mode set by T-MODE changes to 9H and
alarm recording continues until the alarm is
[RECALL] -released.
-
-
3Press the set (+ or -) button to display 9H for
MODE.
MODE 9H
If TAPE END on Menu Screen 4 has been set to REPEAT, the auto repeat recording mode is established when
the tape comes to the end.
With emergency recording, set the unit to the STANDBY or STOP mode.
Alarm Recall
The date and time when the alarm signal was input can be ascertained on the TV monitor by checking the
alarm input time in the RECALL item on Menu Screen 3.
1Set the MENU/REC LOCK switch to MENU to 2Upon completion of the settings, set the MENU/
display the menu screens. Press the page button REC LOCK switch to OFF. The regular screen is
to display the alarm recording setting screen (Menu restored.
Screen 3) on the TV monitor.
[ALARM] P3
MODE : 9H
DURATION : 30SEC
[RECALL] 10-10-01 20:19
14- 9-01 12:05
30- 8-01 08:40
25- 6-01 04:14
[OUTPUT SELECT]
TERMINAL OUT : ERR WARN
The alarm recall function stores up to 4 alarm input times in the memory and displays them on the screen. If
there have been more than 4 inputs, they will be deleted from the screen in sequence starting with the oldest
data.
When the RESET button is pressed while Menu Screen 3 is on the display, the alarm recall memory can be
cleared.