Alarm Recording (Emergency Recording)
When an emergency occurs at the monitoring site during prolonged monitoring and recording, the alarm function
is automatically triggered, and alarm recording is performed.
Principle of Alarm RecordingConnecting the Alarm Input
Connector
Alarm input Alarm reset input
Tape startTape end
RecordingAlarm recordingRecording
Alarm switch
Time lapse modeAlarm modeTime lapse modeCAMERA
SW OUTIN
(9H)AUDIO
OUT
ALARM RESET INTAPE END OUT
When an alarm signal is supplied by an alarm sensor AC IN
WARNING/
(door or intercom switch, etc.) during recording in a ALARM IN COMMONREC INREC OUT
time lapse mode, the recording speed is switched to
the 9-hour mode and the details of the state of Alarm switch
emergency are faithfully recorded.
Alarm reset switch
Alarm and Display Methods during
4 V - 14 V
Alarm Recording
EJECTREC REVIEWREC
RECAlarm recording starts when the alarm switch is set
PULL OPEN
REVFWDon. When the alarm reset switch is set ON after
TRACKING /V-LOCKRESETTIME MODECOUNTER /SEARCH
ALARMrecording has started, alarm recording is released
and operation is returned to the original time lapse
recording mode.
ALARM display lamp
Alarm recording can be released by pressing the
STOP button during alarm recording.
When an alarm signal is supplied, the alarm display However, it cannot be released even by pressing the
lamp functions as follows.STOP button if the MENU/REC LOCK switch is at
REC LOCK or INT is lit on the display.
AlarmOnFlashingOffAlarm recording can be automatically reset without
lampsupplying the alarm reset input signal.
The reset time can be set for 30 sec., 1.0, 2.0, 3.0,
5.0 or 10 minutes.
Alarm inputAlarm reset switch is
inputpressed twice.
Another option is alarm recording only while the alarm
input signal is supplied.
Alarm recording is also possible as far as the end
of the tape.
Display
switch to
?9H?.
17-11-00 9H
10:14:30 A
?A? display
TV monitorappears