Setup menus
TIME CODE
ItemSetting
Description of settings
SuperimposedSuperimposed
No.No.
displaydisplay
500 VITC BLANKFor setting whether to output the VITC signal at the position which is set using
menu items No.501 [VITC POS-1] and No.502 [VITC POS-2].
0000BLANK0: The VITC signal is not output.
0001THRU1: The VITC signal is output.
<Note>
This setting takes effect only with the SD output (VIDEO output and SD SDI
output).
501 VITC POS-1000010LFor setting the position where the VITC signal is to be inserted.
::<Notes>
000616LO The same line as the one selected by menu item No.502 [VITC POS-2] cannot
::be selected.
001020LO If 50i/25P is selected as the menu item No.25 [SYSTEM FREQ] setting, the
setting range is lines 7L to 11L to 22L.
O This setting takes effect only with the SD output (VIDEO output and SD SDI
output).
502 VITC POS-2000010LFor setting the position where the VITC signal is to be inserted.
::<Notes>
000818LO The same line as the one selected by menu item No.501 [VITC POS-1] cannot
::be selected.
001020LO If 50i/25P is selected as the menu item No.25 [SYSTEM FREQ] setting, the
setting range is lines 7L to 13L to 22L.
O This setting takes effect only with the SD output (VIDEO output and SD SDI
output).
503 TCG MODEFor setting the synchronization of the internal time code generator.
0000REGEN0: The time code which is read from the tape by the time code reader is used.
0001PRE1: The mode can be preset using the controls on the operation panel or the remote
controller.
0002AUTO2: REGEN or PRE is automatically selected depending on the operation mode.
Follow-on recording mode: REGEN is selected.
All other modes: PRE is selected.
504 RUN MODEFor setting the operation mode in which the internal time code generator runs.
0000REC0: The generator runs only while recording is in progress.
0001FREE1: The generator runs while the power is on regardless of the unitOs operation
mode.
505 TCG REGENFor setting the signal to be regenerated when the TCG (time code generator) is in
the regeneration mode.
0000TC&UB0: Both the time code and userOs bit are regenerated.
0001TC1: Only the time code is regenerated.
0002UB2: Only the userOs bit is regenerated.
507 TC SOURCEFor selecting the time code to be used when an external time code is used.
0000INT0: The internal time code generator is used.
0001EXT L1: The LTC information of the TIME CODE IN connector is used.
0002SLTC2: The LTC information added to the serial signals which are supplied to the HD
SDI IN connector is used.
0003SVITC3: The VITC information added to the serial signals which are supplied to the HD
SDI IN connector is used.
<Notes>
O When a setting other than INT has been selected for this menu item, the userOs
bit of the LTC and VITC which is output during recording may be output with a
delay of 1 frame from the time code.
O When O1394� is selected as the menu item No.600 [VIDEO IN SEL] setting and
a setting other than INT is selected for TC SOURCE, the time code which is
input to the DV connector is used.
At this time, the VITC information will not be superimposed onto the video signal
output when recording is performed or the E-E mode is established. The LTC
information and VITC information are not superimposed onto the HD serial
output signals.
O� indicates the factory setting.