Setting the Fan Speed Setting the Horizontal Airflow DirectionENGLISHOperation Details
Y Press 4 to select:-
FAN� Low Fan SpeedCOOL � Cooling Operation
FAN� Medium Fan SpeedY To set the room temperature at your preference
FAN� High Fan Speedcooling comfort.
AUTO
FAN� Automatic Fan SpeedAUTO � Automatic Operation
EEEECCCCOOOONNNNOOOOMMMMYYYYPPPPOOOOWWWWEEEERRRRFFFFUUUULLLLPPPPOOOOWWWWEEEERRRR QQQQUUUUIEIEIEIETTTTTTTITIIMIMMMEEEERRRR
The speed of the indoor fan is adjustedY Sense indoor temperature to select the optimum
automatically according to the operation.mode.
The indoor fan stops occasionally duringY Temperature is not displayed on the remote control
Y Adjust it manually
cooling operation.during AUTO operation.
Use this air conditioner under the following
Setting the Vertical Airflow DirectionDRY � Soft Dry Operation
conditions:
Y Press 5 or 6 to select:-Y A very gentle Cooling Operation, prior to
dehumidification. It does not lower the room
Cooling Modeltemperature.
Cooling Model
Y During Soft Dry operation, the indoor fan operates at
COOL / DRY OperationFAN Operation(Unit in !F)Low fan speed.
AUTOAUTO
IndoorOutdoor
DBT: Dry Bulb Temp
HEAT � Heating Operation
WBT: Wet Bulb Temp
DBT WBT DBT WBT
(for Heat Pump Model only)
Y Heat is obtained from outdoor air to warm up the
Maximum Temperature89.6 73.4 109.4 78.8
36!61!room. When the outdoor ambient air temperature
Minimum Temperature60.8 51.8 60.8 51.8falls, the heating capacity of the unit might be
reduced.
Swing up/downMove up/down
Y Defrosting Operation
AutomaticallyAutomatically
Depending on the outdoor temperature, the operation
Heat Pump Model
MANUALoccasionally stops to melt the frost on the outdoorMANUAL
Five stages of adjustmentFive stages of adjustment
unit.
(Unit in !F)
can be made betweencan be made between
14 ~ 36 angle.0 ~ 61 angle.IndoorOutdoor
DBT: Dry Bulb TempFAN � Air Circulation Operation
WBT: Wet Bulb Temp(for Cooling Model only)
Heat Pump ModelDBTWBTDBTWBT
Y When the room temperature reaches the set
Maximum Temperature-Cooling 89.6 73.4 109.4 78.8
COOL / DRY Operationtemperature, operation commences at Low airflowHEAT Operation
(�) (75.2) (64.4)(Maximum Temperature-Heating)(86)
volume. It stops when the room temperature drops to
AUTOAUTO
4!F below the set temperature.
Minimum Temperature-Cooling60.851.860.851.8
� When the discharge air
(It is useful when using a heater).
(Minimum Temperature-Heating)(60.8)
temperature is low such(�)(23)(21.2)
Y Hi fan speed will not operate when using the air
as at the start of heating
circulation Fan mode.
operation, the air blows
36! Notes
in a horizontal direction.
Y If the unit is not going to be used for an extended
As the temperature
period of time, turn off the main power supply. If it is
rises, the hot air blows
Swing up/downleft at the ON position, approximately 2.5 W of
in a downward direction.
Automatically
� To stop this operation,electricity will be used even if the indoor unit has been
press MANUAL.turned off with the remote control.
Y If operation is stopped, then restart immediately, the
MANUALMANUAL
Five stages of adjustmentFive stages of adjustmentunit will resume operation only after 3 minutes.
can be made betweencan be made between
14 ~ 36 angle.0 ~ 61 angle.
6 |