5ECONOMY OPERATIONCHECK TIMER SETTING DURING OFF TIMER
ECONOMY!FTo reduce power consumption:!FPress the TIMER button to check the
hrY Press ECONOMY.TIMERhrremaining programmed timer setting.
ECONOMYY To cancel this operation, press onceThe figure will be displayed for 10
more.!Fseconds then will automatically switch
hrback to temperature setting.
ECONOMY
NOTE
Recommended for electricity cost saving. When economy button
is pressed, target temperature is shifted up 1!F, this will reduceThe timer figure will change accordingTIMER
operating time of the compressor and therefore reduce powerto the time remaining (if you set it to turn
consumption. It may, however, take a little longer for theoff 3 hours from now, the timer will show
compressor to cycle on and thereby increase the roomO2� at an hour later).
temperature slightly. Economy mode will override your current
set fan speed to OLOW�. However, the display will still show the
CANCEL TIMER SETTING DURING OFF TIMER
current set fan speed. Compressor stops when the room
temperature reaches the target temperature. It turns on againSETPress the SET/CANCEL button to
!FSET/
when the room temperature rises. When power failure occurs,CANCELhrcancel the timer setting. The SET/
the economy setting is canceled. Once power is resumed, resetCANCEL indicator light will turn off.
SET/
the economy setting.CANCELHowever the temperature remains
displayed.
SETTING THE OFF TIMER
AIR CONDITIONER OPERATION!FWhen the air conditioner in operation:TIMER
hrPress the TIMER button.
The SET/CANCEL indicator light will
TEMP/TIMER!Fblink awaiting for setting.
hrPress the TEMP/TIMER s or t button
SETuntil the preferred hour of operation is
SET/!Freached.
CANCEL
hrPress the SET/CANCEL button to
complete the setting. At this time, the
SET/CANCEL indicator light is steady
instead of blinking.
NOTE
TIMERThe hour reading will change back to the
set temperature reading after 10
TEMP/TIMERseconds. (You can also revert to
temperature setting immediately by
SET/pressing the TEMP/TIMER s or t
CANCEL
buttons again.)
ModelCW-XC122VU
COOLING CAPACITYBtu/h11,500
6
ELECTRICAL RATINGPhaseSingle
Frequency(Hz)60
Voltage(V)115
Current(Amps)10.1
Input(W)1150
EER(Btu/W.h)10.0
MOISTURE REMOVAL(Pints/h)3.0
ROOM AIR CIRCULATION(Cf/min)330
DIMENSIONSHeightcm (inches)37.5 (14-25/32ý)
Widthcm (inches)56 1/(22-16ý)
27
Depthcm (inches)60.6 (23-/32ý)
NET WEIGHTkg (lb)35 (77)
GROSS WEIGHTkg (lb)39 (86)
NOISE LEVELIndoor (Hi/Lo)dB (A)51/47
Outdoor (Hi/Lo)dB (A)58/55
* Specifications are subject to change without notice for further improvement.