AR-150E
[4] SIMULATIONS
The following items are added in this model. (Not provided in the AL series.)
1. List of simulations
Main codeSub codeContents
5Lamp ON check01Operation panel display check (Maintenance lamp added)
02Fusing lamp ON + cooling fan high speed/low speed
03Copy lamp ON
20Maintenance01
counter clear
21Counter setup01Maintenance cycle setup
(In
maintenance)
22Counter display01Maintenance counter
02Maintenance preset value
05Total counter
12Drum counter
14P-ROM version display
21Scanner counter
2. Contents of simulations
Main codeSub codeContentsDetails of operation
2001MaintenanceWhen the PRINT switch is pressed, the maintenance count value is cleared and the
counter clearvalue (000000) is displayed.
2101MaintenanceThe code of the currently set maintenance cycle value is displayed (initial display), and
cycle setupthe set data is stored.
Key operation/Display
CodeSetup
03,000 pages
16,000 pages
29,000 pages
313,000 pages
418,000 pages
5Free (999,999 pages) Default
2201MaintenanceThe display method is similar to the total counter display.
counter display
02MaintenanceThe quantity corresponding to the code set with 21-01 is displayed.
reset valueThe display method is similar to the total counter display.
display
05Total counterThe total counter value is displayed in 3 digits x 2 times repeatedly.
display
Display
(example: 12345)
012 ? Blank ? 345 ? Blank ? 012
0.7s 0.3s 0.7s 1.0s 0.7s
12Drum counterThe display method is similar to the total counter display.
display
14P-ROM versionThe P-ROM version is displayed in 3 digits on the value display section.
display(In the AR model, the 100% zoom lamp is displayed.)
21ScannerThe display method is similar to the total counter display.
counter display
4 - 1 |