INSTALLATION AND USER INSTRUCTIONS FORConnecting to mains supply
COOKER HOODS TYPE ?EX 77? - ?EX 77 TWIN?Check that the mains supply is the same as that on the technical
data plate which is attached to the cooker hood.
Attention: If the appliance has no plug an allpole separation
These instructions should be read carefully
must be provided in the separation of the net with a minimum
before the installation is donecontact width of 3 mm each pole.
Your new cooker hood can be used in the following ways:Note ? A damaged power supply cord must be changed by the
Service because require a special tool.
Extraction (exhaust mode) - Fig. 1
In this case it is necessary to connect the hood to a tube (OMaintenance
100?125 mm.) by using the connection piece which is supplied.N.B. Before any repairs, servicing or cleaning is carried out the
The extracted air is then expelled to the outside. Check that theplug must be disconnected.
lever extraction/recirculation is in the position of Extraction (Fig.
The grease filter should be washed every 10-15 days in hot water
3/B). For two motors turn the knobs A and B in the way as
with detersive. It absorbs the particles of fat which become present
indicated by the arrows (Fig. 4). For the evacuation of the
during cooking and protects the kitchen and its furniture from
exhausted air please note ufficial instructions.
deposits of grease. After successive washings however it should
be replaced.
The carbon filter functions during any type of cooking and is
highly effective removing cooking smells and particles of grease
Recirculation (filtering mode) - Fig. 2
which otherwise would be deposited on the walls and the fur-
The air is purified by means of an active carbon filter (odour filter)
niture. Carbon filters cannot be washed. It is advisable to replace
and then returned into the room. Check that the lever extraction/
them every six months, depending on how frequently the hood is
recirculation is in the position of Recirculation (see Fig. 3/B),
in use.
that the top grid of the hood is not obstructed and that there is a
In order to replace the filters mentioned above it is sufficient to
carbon filter fitted (see Fig. 3/C). For two motors turn the knobs
open the grid of the cooker hood by pushing the fixing devices
A and B like in the figure (Fig. 4).
one towards the other pulling the grid outside until the control
board is freed. The grease filter can be taken off by removing the
Summer/Winter useretaining clips that hold it in its place, while the carbon filter can
To avoid loss of heat in winter it is advisable to use the hood asbe freed by turning counter clockwise.
a recirculation hood. Warm air is purified and then re-distributedThe external parts of the cooker hood should be cleaned by using
into the room. Cooker hoods which are installed as extractiona damp sponge and liquid neutral detersive or a cloth dipped in
hoods are easily changed to recirculation hoods and vice-versa.neutralised alcohol.
Please avoid cleaning products that contain scouring agents.
Installation
The cooker hood must be fixed directly under a kitchen unit,Security regulations
furthermore it must be installed centrally above the cooking hob.Cooking ?en flambe? under the cooker hood is forbidden. When
The minimum distance between the hob and the lower part of thefrying, constant watch must be given to all aspects of the ope-
cooker hood must be 650 mm.ration in particular because oil heated to a high temperature
N.B. The above distance is subject to regulations in force forbecomes inflammable easily.
security in the respective countries.Frequent cleaning, in particular of the fan and the surfaces of the
cooker hood, will avoid the risk of fire. The cleaning can be done
Extraction Hoodwith a cloth or small brush dipped in ethyl alcohol. Furthermore
When used in the extraction mode following points should beit is important to replace frequently each of the filters fitted in the
cooker hood.
considered: The exhausted air should not be conducted in a
chimney with warm air circulation. Do not connect the appliance
to fuel exhaust flues or ventilating ducts. With venting into exhaustSuggestions for the use in extraction mode
flues or ventilating ducts wich are no longer in use, it is advisable
(exhaust version)
to obtain the approval of the responsible agency for the building.
When the cooker hood is used in the extraction mode it is advisable
In the extraction mode the air is exhausted and conveyed through
to give particular attention to appliances and sources of heating
the ventilating duct upwards or directly to the outside.
at the same time in use (e.g. gas and oil heaters, coal or coke
Attention: The shorter the exhaust duct is and the fewer bends
fires etc.) because the cooker hood sucks in the air which is
there are in it, the more effective will the cooker hood be.
needed for combustion by the above mentioned appliances causing
a depression.
Recirculation Hood
During simultaneous use of heating appliances and cooker hood
When the hood is used in the recirculation mode and fitted with
a max. depression of 0,04 mbar is advisable. In these conditions
a carbon filter there is no need to connect the device (connectionthe risk of drawing in gases from heating appliances is avoided.
piece) to the tube.
This can be obtained by openings which cannot be closed e.g. in
doors and windows or by other technical means. From these
Installation under a Kitchen Unit
openings sufficient fresh air for combustion should be able to
N.B. Check that the unit is able to support the weight of theenter.
cooker hood.
Attention: To assess the situation fully all flues and vents in the
Turn the unit upside-down.
apartment should be taken into consideration. If there is any doubt
Mark the holes for the screws.
then it is advisable to obtain the approval of the responsible
Corresponding to the air-outlet a hole for the connection piece of
agency for the building. These precautions are not required when
O 104/140 mm must be provided on the kitchen unit (for spigot
the cooker hood is used in the filtering version with carbon filter
of O 100/125 mm).
fitted.
Drill the holes for fixing the hood with a O 5 mm drill-bit.
Lean the unit against the top part of the cooker hood and tighten
it up to the hood with the 4 self-threading screws. |