2 l Pick the right window. First, decide what 5 l Leveling air conditioner is not required in a
normal installation. The proper slope is
room(s) you want to cool. Then choose a designed into the product. However, be sure
window that will allow the air-conditioned
air to flow freely and directly into the room(s) you have approximately a one-half bubble
you want cooled. Remember, it?s difficult to (1/?) downward tilt to the outside for proper
move air around corners. Choose a window water drainage (see Figure 9). If necessary,
that?s also near an electrical outlet. (Refer to reposition or shim cabinet to provide the
the ELECTRICAL REQUIREMENT pages proper tilt or side-to-side leveling
for type of receptacle and wiring needed.)
Do not use an extension cord. The window in
which you place your air conditioner should
have an opening of at least 25 inches in width
and at least 16 inches in height (see Figure 6).
Standard installation parts are supplied for
double-hung sash windows up to 38 inches in
width.
6 l Pull out sliding curtains while holding air
conditioner in window. Extend curtains on
both sides until they engage window channels.
Pulling slightly inward allows curtains to slide
easily. Mark and make 3/32? pilot holes
before installing thumb screws in side handles
3 l Remove front panel by pushing it down and
pulling toward you (see Figure 7). This pro- of curtains (see Figure 10). Or, if space is a
tects the panel from damage and makes the problem, use holes in top flanges of curtains.
air conditioner easier to handle during in- (CAUTION: BE SURE UNIT DOES NOT
FALL OUT OF WINDOW.)
stallation.
4 l Center air conditioner in window. Rear of
unit must be raised slightly to position lower
rail of air conditioner behind and up against
back side of window sill ( see Figure 8).
CAUTION: BE SURE UNIT DOES NOT
FALL OUT OF WINDOW.) Lower the
window sash firmly behind the top mounting
channel. 7 l Install window rail seal and window lock
bracket. Press foam window seal into place
and cut to proper length (see Figure 11).
Mark and make a 3/32? pilot hole, then install
lock bracket using roundhead screw.
(CAUTION: KEEP WINDOW LOCK
INSTALLED AT ALL TIMES TO BE SURE
UNIT DOES NOT FALL OUT OF WINDOW.
REMOVE ONLY WHEN YOU WISH TO
REMOVE AIR CONDITIONER FROM
WINDOW.) Seal small openings around
installation with gum-type sealer.
7 |