Location RequirementsElectrical Requirements
IMPORTANT: Observe all governing codes and ordinances.
Check the location where air conditioner will be installed. Proper
installation is your responsibility. Make sure you have everything WARNING
necessary for correct installation.
The location should provide:
Grounded electrical outlet within 4 ft (122 cm) of where the
power cord exits the air conditioner.
NOTE: Do not use an extension cord.
Free movement of air to rooms to be cooled.
A large enough opening for the air conditioner. Installation
parts are supplied for double-hung windows.Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Adequate wall support for weight of air conditioner. Air
conditioner weighs 56 lb (25 kg) to 91 lb (41.28 kg).Do not remove ground prong.
NOTE: Cabinet louvers must not be obstructed. Air must be able Do not use an adapter.
to pass freely through the cabinet louvers.
Do not use an extension cord.
AFailure to follow these instructions can result in
death, fire, or electrical shock.
The electrical ratings for your air conditioner are listed on the
model and serial number label. The model and serial number
label is located behind the front panel on the front flange above
the coil area.
Specific electrical requirements are listed in the chart below.
Follow the requirements for the type of plug on the power supply
cord.
Power supply cord
plug outletWiring requirements
115 volt (103.5 min. -
A.Cabinet louvers126.5 max.)
0-12 amps
Window installation15-amp time-delay fuse or
circuit breaker
Use on single outlet circuit
only.
230 volt (207 min. -
253 max.)
1D?"
(0.6 cm)230/208 volt (197.6 min. -
253 max.)
0-12 amps
A15-amp time-delay fuse or
Bcircuit breaker
Use on single outlet circuit
only.
Window opening measurements
Air Conditioner SizeAB
5,000-7,000 Btu/h25" to 38" 14"
(63.5 cm to (35.6 cm)
96.5 cm)
8,000-12,000 Btu/h26" to 38" 16"
(66 cm to (40.6 cm)
96.5 cm)
4 |