Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
Window installation
Check the location where the air conditioner will be installed.
Make sure you have everything necessary for correct installation.
Window opening measurements:
The location should provide:
 24" (61 cm) minimum to 36" (91.4 cm) maximum opening
 Grounded electrical outlet within 4 ft (122 cm) of where the
width.
power cord exits the air conditioner.
 15" (38.1 cm) minimum opening height.
NOTE: Do not use an extension cord.
 Free movement of air in room to be cooled.
 A large enough opening for the air conditioner. Installation
parts are supplied for double-hung windows.
 Adequate wall support for weight of air conditioner. Air
conditioner weighs 71 lbs to 135 lbs (32.2 kg to 61.2 kg).
NOTE: Cabinet louvers must not be obstructed. Air must be able
to pass freely through the cabinet louvers.
A
B
A
A.24" (61 cm) minimum
A
B.15" (38.1 cm) minimum
A.Cabinet louvers
Electrical Requirements
Specific electrical requirements are listed in the chart below.
Follow the requirements for the type of plug on the power supply WARNING
cord.
Power supply cord Wiring requirements
 115-volt (103.5 min. - 126.5 max.)
 0-12 amps
 15-amp time-delay fuse or
Electrical Shock Hazardcircuit breaker
Plug into a grounded 3 prong outlet. Use on single outlet circuit only.
Do not remove ground prong.
Recommended Grounding MethodDo not use an adapter.
Do not use an extension cord.This air conditioner must be grounded. This air conditioner is
equipped with a power supply cord having a grounded 3 prong
Failure to follow these instructions can result in death,
plug. To minimize possible shock hazard, the cord must be
fire, or electrical shock.
plugged into a mating, grounded 3 prong outlet, grounded in
accordance with all local codes and ordinances. If a mating outlet
is not available, it is the customer's responsibility to have a
The electrical ratings for your air conditioner are listed on the
model and serial number label. The model and serial number properly grounded 3 prong outlet installed by a qualified electrical
installer.
label is located on the right-hand side of the air conditioner
cabinet.
4 |