Proper installation of your air conditioner is important for proper operation and best cooling results. This
section will tell you how to meet necessary electrical requirements and how to install your air conditioner
properly into a sliding or casement style window. Please read these installation instructions, as well as
the operating and care instructions, before installing your unit.
Meeting electrical requirements
OBSERVE ALL LOCAL CODES AND
ORDINANCES.
Elactrlul Shock and DO NOT, UNDER ANY CIRCUMSTANCES,
Person81 Injury Hazard REMOVE THE POWER SUPPLY CORD
GROUNDING PRONG.
l Electrical ground is required on this
appliance. NOTE: lf codes permit and a separate grounding
l DO NOT modify the power supply cord wire is used, it is recommended that a qualified
plug. lf it does not fit the outlet, have a electrician determine that the grounding path is
proper outlet installed by a qualified adequate and not interrupted by plastic, non-
electrician. metallic gaskets or other insulating materials.
l DO NOT have a fuse in the neutral or Receptacle wiring
grounding circuit. A fuse in the neutral or Receptacle wiring should be a minimum of
grounding circuit could result in an
electriial shock 14gauge. Use copper wire only. It is the respon-
sibility of the consumer to provide proper and
l DO NOT use an extension cord with this adequate receptacle wiring, installed by a
appliance. qualified electrician. Observe the National
l Check with a qualified electrician if you Electrical Code and all local governing codes and
are in doubt as to whether the appliance ordinances.
is properly grounded.
Electrical requirements
Failure to follow these instructions could
resutt in electrical shock, serious injury A 115 volt (103.5 minimum, 126.5 maximum),
60 Hertz, AC only, 15 ampere fused electrical
or death.
supply is required. A time delay fuse or time
delay circuit breaker is also required. A separate
circuit, sewing only this appliance, must be
provided.
5 |