Electrical Connection Requirements
WARNING
To avoid the risk of serious electrical shock or
property damage, do not cut or remove the third
(ground) prong from the power plug. A 3- wire
CC30 Wall Cap with Flap = 71/2 Ft.grounded conductor system must be used. Relying
(available from dealer)on the flexible connector, hard piping or any other part
of the gas supply line as a ground may cause fire,
electrical shock and/or erratic control operation.
Anti-tip Bracket Installation
To reduce risk of range tipping, secure range with aRange must be electrically grounded in accordance with
properly installed anti-tip devise packed with range.local codes or in the absence of local codes, with the
National Electrical Code, ANSI/NFPA No. 70-Latest
1
1. Measure 5/8 inches from back wall on right and leftEdition. In Canada, electrical connections are to made in
side of cabinet cutout. Mark measurements on flooraccordance with CSA C22.1 Canadian Electrical Code.
and draw a straight line connecting marks.
2. Position anti-tip bracket.Use a 120 volt, 60 hertz 3 prong receptacle protected by
? If range is installed beside cabinet(s), place anti-tipa 15 amp circuit breaker or time delay fuse.
bracket with inside edge over line drawn on floorA qualified electrician should confirm the outlet is
and end of bracket against cabinet.properly grounded.
? If range is not installed beside cabinet(s), position
range where it will be installed. Draw a line alongIf a 2 -prong outlet is encountered, range owner must
side of range on floor from front to back. Removereplace outlet before using range. Do not cut off cord or
range. Place anti-tip bracket with inside edge overremove grounding plug.
1
line drawn 5/8 inches from back wall and end of
bracket over line drawn along side of range on floorRange wiring diagram is located on the bottom of the.
? Anti-tip bracket can be installed on either right orstorage drawer.
left side.
Electrical Connection Clearance
Electrical connection must be located in the shaded area
shown in Figure below. Electrical connection must not
interfere with gas connection.
3. Mark 2 hole locations in anti-tip bracket.5"
5"
4. Drill 2 holes.18"
3
? If drilling into wood, use a /32 inch drill bit.
3
? If drilling into concrete, use a /16 inch masonry drill
bit and insert plastic anchors.
5. Secure bracket to floor using screws supplied.10"
8 |