Operation
Testing for Gas LeaksOperating Burners
After final gas connection is made, turn on manual gas1. Push and turn burner control knob to LITE position.
valve and test all connections in gas supply piping and? Burner sparks until gas ignites.
cooktop for gas leaks.2. Turn burner control knob to desired setting.
3. Turn burner control knob to OFF position when
finished.
WARNINGDelayed Ignition
Burner should ignite within 4 seconds. If burner does not
To avoid property damage or serious personal
injury, never use a lighted match to test for gasignite within 4 seconds turn control knob to OFF position.
leaks.Try burner again. If burner still does not ignite in 4
seconds, contact an authorized servicer.
1. Place soap suds on connection.Adjusting Burner Flame
? Bubbles appear if leak is present.Properly adjusted burner flames are clean and blue with a
2. If bubbles appear, shut off gas supply valve.distinct inner cone approximately 1" to 1" long.
3. Tighten joint if leak is at factory fitting.
? If burner flame is too large or small, See Adjusting
? If leak is not at factory fitting, unscrew, apply moreBurner Flame Size section.
joint compound, and tighten to correct leak.? If burner flame is blowing or noisy, reduce airflow to
4. Retest connection for leak after tightening.
burner. See Adjusting Airflow to Burner section.
? Retest any connections that were disturbed.? If burner flame is soft and lazy, increase airflow to
burner. See Adjusting Airflow to Burner section.
Electrical Installation Requirements
Installation of this product must conform with local codes
or in the absences of local codes, with current Canadian
Gas Installation Code CAN/CGA-B149.2. If an external
electrical source is used when the appliance is installed,
it must be electrically grounded in accordance with local
codes or, in the absence of local codes, with the current
Adjusting Airflow to Burner
National Electric Code ANSI NFPA 70, or CSA Standard1. Remove control knobs, grates, and burner bowls.
C22.1, Canadian Electric Code, Part 1.
2. Remove screws attaching burner top to burner box.
? Screws located in burner cutout on outer edge.
All electrical connections are to be made in accordance
with CSA Standards Z240.6.1 electrical requirements for3. Loosen air shutter lock screw.
mobile homes.
Use a 120 volt, 60 hertz, 3-prong receptacle protected by
a 15 amp circuit breaker or time delay fuse.
A qualified electrician should confirm the outlet is
properly grounded. Cooktop includes 4 foot power cord
attached to bottom of cooktop at back, left corner.
4. Open or close air shutter depending on appearance
If a 2-prong outlet is encountered, cooktop owner mustof burner flame.
replace outlet before using cooktop. Do not cut off cord or5. After burner flame is properly adjusted, tighten air
remove grounding plug.shutter lock screw.
6. Reassemble cooktop.
Adjusting Low Burner Flame Size
1. Push and turn burner control knob to LITE position.
? Burner sparks until gas ignites.
2. Set flame to low position.
3. Remove burner control knob.
4. Hold valve stem and turn screw in center of burner
control stem using small standard screwdriver until
flame is adjusted.
5. Replace control knob.
6. Push and turn burner control to test burner flame.