NC
INSTALLATION
Electrical connectionxWhenthecookinghobisinstalled,provide
xTheelectricalconnectionsmustcomplya singleîpole circuit breaker with a contact
with local regulations.breakingdistanceofatleast3mm.
xThedatarelevanttothevoltageandpowerxAfterinstallation,theelectricpartsmust
absorption are indicated on the rating plate.not be accessible.
xTheearthingofthisapplianceisxThecookinghobmustbeearthedandfitted
with fuses adequate to the hotplate rating.
compulsory by law.xForelectricalconnection,useanH05RRîF
The manufacturer cannot be heldcable �see table in product description sheetO.
responsible for injury to persons or animals
or damage to property arising from failure
to comply with these requirements.
ELECTRICAL COOKING HOBS
WITH SIDE CONTROLS
Connection to terminal board
1. Open the cover of the terminal board and
loosen screwa by means of a tool, as shown
in the figure.
2. Unsheath the cable for about 70 mm.
3. Peel off the internal cables for about 10 mm,
loosen cable clamp screwb , and insert the
cable in the cable clamp.
xTheterminalboardhas4terminals:
1î2 interconnected �lineO
3 �neutralO
4 �earthO: marked with symbol4 .
4. Connect the cable to the terminal board,
following the indications of the connection
diagram punched on the bottom of the
cooking hob. Fasten the cable clamp and
close the cover.
57
MY
57 |