Double Insulated ToolsOperating the Tool
" Double Insulationis a design concept
used in electric power tools which eliminatesAir flow setting:
the need for the three wire grounded power cordThe air flow is set steplessly with air flow
and grounded power supply system. It is ablower speed dial 3. A lower air stage may be
recognized and approved system byrequired in certain cases, e.g. to avoid over-
Underwriters Laboratories, CSA and Federalheating the workpiece's surroundings or to
OSHA authorities.
avoid displacing the workpiece if the air flow
IMPORTANT: Servicing of a tool withis too strong. A higher air stage heats up the
double insulation requires care and knowledgeworkpiece more quickly and enables the hot air
of the system and should be performed only bygun to be held at a greater distance from the
a qualified service technician. WHEN SER-workpiece.
VICE IS REQUIRED USE ONLY IDENTI-
CAL REPLACEMENT PARTS.ON/OFF switch
POLARIZED PLUGS: If your tool is equippedI(Cool air stage) 8.8 CFM a120oF.
with a polarized plug (one blade is wider thanFor cooling down a hot workpiece or for drying
the other), this plug will fit in a polarized outletpaint.
only one way. If the plug does not fit fully in the
outlet, reverse the plug. If it still does not fit,II(Hot air stage) 17.8 CFM a1100oF.
contact a qualified electrician to install the
Temperature control (thermo-electronic):proper outlet. To reduce the risk of electric
shock do not change the plug in any way.The temperature can be controlled steplessly
with the setting dial 5 and switch 6 in setting II.
OThermo-electronic
Extension Cords
Y1th3ermo-e
le
Yctron
" Replace damaged cords immediately. Use of5icY1
I57Y
damaged cords can shock, burn or electrocute.IIY9Y31
III!F!C
" If an extension cord is necessary, a cord with
I1-1512050
adequate size conductors should be used to
112050
prevent excessive voltage drop, loss of power
3210-310100-155
or overheating. The table below shows the5400-480205-250
correct size to use, depending on cord length7520-570270-300
II
and amperage rating on the tools nameplate. If9700-740370-395
in doubt, use the next heavier gauge. Always11870-920465-495
13960-1010515-545
use U.L. and CSA listed extension cords.
151050-1100565-595
Ampere Rating (shown on nameplate)
0-2.1- 3.5- 5.1- 7.1- 12.1-
2.03.45.07.012.0 16.0If the nozzle is hot or if you wish to have both
hands free when working, you can set the tool
25'181818181614
down in an upright position on its base.
50'181816161412
75'181816141210
100'1816141210Temperature displays:
150'16141212 Wire Gauge
Cord LengthThe temperature is displayed via LED 4. By
carefully controlling the air flow and tempera-
Note: The smaller the gauge number, the largerture, very precise work can be performed on
the wire is in the cord.temperature sensitive electrical fittings, pack-
aging, and other materials.
"SAVE THESE INSTRUCTIONS"
6