Error code definition
In case of non-intermittent faults, clear the error buffer before starting the repair. Make sure ?old? error
codes are not present. If possible check the entire content of the error buffers. In some situations an error
code is only the result of another error code (and not the actual cause).
Note: A fault in the protection detection circuitry can also lead to a protection.
Error codes 01,02, 03, and 04 are protection codes, and in this case the supplies of some circuits will be
switched off. Also in protection, the LED will blink the number of times equivalent to the most recent error
code.
ErrorDescription
Code
1NVM (M24C32)
2HFB protection
3Picnic (SAA4978)
45VProtection
58V Protection
6 Slow I2C bus blocked
8HIP I/O-video processing (TDA9320)
9Wireless Expander (PCF8574)
12Topic (LTP Peaking) (TDA9178)
13Tuner Protection
14ITT sound processor (MSP3411/3412/3452)
153D Combfilter protection (?PD64083)
16Feature Box Protection (FBX)
17I/O Expander HD Interface (M62320P)
18Fast I2C bus blocked
19Auto Scavem DAC (TDA8444)
21PIP I/O Expander (M62320P)
22PIP BOCMA (TDA888X)
23PIP Tuner
24PIP Muppet (SAB9081)
25PIP V-Chip (Z86130)
26Falconic (SAA4992)
27Eagle device
28Back Current loop
32Flash Ram (EPG)
36Light engine shutdown Protection Error
37Light engine shutdown protection. Spontaneous blinking 37-37-37.
38Lamp Failure.
39Light engine polarizer fan failure, protection error.
41Shutdown protection error, spontaneous blinking 41-41-41. GDE not responding
42Not protection error. GDE NVM error
43Fan Fault. Not protection error. Shut down if error exists continuously for 2 minutes
44Ambient Temperature Warning. Not protection error. Message should be displayed for
6 seconds and every 15 minutes as long as temp is above ambient temp.warning
45High temperature alert. Not protection error. Shut down message should be displayed
and system should enter standby after 1 minute if the temperature exceeds this limit.
46Audio fault (audio board). Not protection error.
47Audio fault (audio board). Not protection error.
48Thermo cutoff SW. Protection error |