AJ-HPX3000G(VQT1D27)E.book 24 2T87887437E
Time Code Section
456
7
1328
1.GENLOCK IN connector (BNC)6.DISPLAY (counter display selector) switch
This connector is used to input a reference signalIndications of the time code, CTL and user bits on the
before the camera unit is gen-locked, or before thecounter of the display window depend on the positions
time code is externally locked. of this switch and the 7.TCG switch.
Pressing the 4.HOLD button also displays Date/Time/
2.TC IN connector (BNC)Time Zone.
This connector is used to input a reference time codeUB: User bits/DATE/TIME/Time zone indicated.
when you externally lock the time code.TC: Time code indicated.
3.TC OUT connector (BNC)CTL: CTL indicated.
When you inter-lock the time code of camera-recorder7.TCG (time code selector) switch
with that of an external device this must be connectedThis switch is used to specify the stepping mode for
with the time code input (TC IN) connector of thethe built-in time code generator.
external device.
F-RUN: Select this position to continuously advance
? Notethe time code independently of the P2 card
The time code must be input in the same format as therecording status.
system mode of the camera-recorder.Use this mode to synchronise the time code
with the time of day, or to externally lock the
4.HOLD buttontime code.
Pressing this button freezes the time data indicationSET:Select this position to set the time code and/
on the counter. Note that time code generationor user bits.
continues. Pressing the button again reactivates theR-RUN: Select this position to advance the time code
counter.only during recording.
This function is used to ascertain the time code or CTLFor spliced scenes recorded on P2 cards,
count of a particular recorded scene. the sequence of time codes is unbroken.
5.RESET button8.CURSOR and SET buttons
This button resets the time data (CTL) on the counterUse these buttons to set the time code and user bits.
to ?00:00:00:00?.The four triangular buttons are the CURSOR buttons,
If this button is pressed when with the 7.TCG switchand the center rectangular one is the SET button.
positioned at [SET], time code and user bits data areFor guidance in setting the time code and user bits,
reset to 0, and real-time data is reset to the initialsee [Setting Time Data] (page 55).
value.
24Parts and their FunctionsTime Code Section |