Converting Burners for Use withConverting Type 1 Pressure Regulator for
LP\PropaneUse with Natural Gas
1. Remove grates, burner bowls, and burner control1. Remove pressure regulator cap using a wrench.
knobs from cooktop.2. Remove plastic insert from pressure regulator cap.
2. Remove 2 screws attaching burner top to burner box.? Plastic insert fits tightly in cap.
? Located in burner cutout on outer edge. 3. Reverse plastic insert and carefully push plastic
3. Remove screws attaching burners to support bracket.insert firmly into hole in pressure regulator cap.
4. Remove burners and venturi tubes.? Insert must show ?NAT? or be blank.
5. Unscrew orifice hoods and remove.4. Place pressure regulator cap on pressure regulator
? Natural gas orifice hood has a larger hole thanand tighten.
LP hood.? Insert should not disturb spring in body of regulator.
? Natural Gas Orifice?#56
? LP Orifice?#68
Converting Type 2 Pressure Regulator for
6. Remove manifold cover.
Use with Natural Gas
7. Locate orifice hoods (#68) wired to gas manifold and
1. Remove pressure regulator cap using a wrench.
screw onto valve.
2. Reverse pressure regulator cap.
? Do not overtighten orifice hoods.
? Insert shows ?NAT? or is blank.
8. Attach unused orifice hoods to manifold
3. Place pressure regulator cap on pressure regulator
for future use.
and tighten.
Converting Burners for Use with
Natural Gas
1. Remove grates, burner bowls, and burner control
knobs from cooktop.
2. Remove screws attaching burner top to burner box.
? Located in burner cutout on outer edge.
3. Remove screws attaching burner to support bracket.
4. Remove burner and venturi tube.
5. Unscrew orifice hoods and remove.
9. Reassemble cooktop.
? Natural gas orifice hood has a larger hole than
LP hood.
? Natural Gas Orifice?#56
? LP Orifice?#68
6. Remove manifold cover.
7. Locate orifice hoods (#56) wired to gas manifold and
screw onto valve.
? Do not over tighten orifice hoods.
8. Attach unused orifice hoods to manifold
for future use.
9. Reassemble cooktop.
6 |