#1 Electronic Shutter Mode Setting [Shutter Mode:Notes
Step/ ELC/ S/Scan]" In case of using the RCU (RCB), none of the
Step: Electronic shutter operates at the speedshutter speeds1/250, 1/2 000, 1/4 000, and
selected by the Electronic Shutter Step Setting1/10 000 can be selected.
#2." In case of using the hybrid control panel, only
ELC: Electronic shutter is controlled to automatical-OFF, 1/100, or ELC can be selected.
ly adjust the luminance." If the lens iris switch is at M (Manual) when oper-
S/Scan (Synchro Scan):Electronic shutter oper-ating the camera alone or when the iris switch on
ates at the speed selected in Electronic Shutterthe RCU (RCB) is at AUTO, ELC may not func-
Synchro-Scan Setting #3.tion. Set the lens iris switch to A (Auto).
" Flickering may increase at ELC under fluores-
Note
cent lights.
If Frame 1 is selected in CCD Read Out Mode
Setting #4, Electronic Shutter Mode Setting cannot
be added.#3 Electronic Shutter Synchro-Scan Setting
[Synchro Scan: 60.34 Hz - 15.75 kHz]
This setting is possible only when Electronic Shutter
#2 Electronic Shutter Step SettingMode Setting #1 is at S/Scan.
[Step: OFF/1/100 - 1/10 000]Bar noise can be reduced by synchro-scan adjust-
This setting is possible only when Step is selectedment in shooting workstation scenes, for example.
in Electronic Shutter Mode Setting #1.
*For luminance setting at each shutter speed and
OFF: Electronic shutter is turned off.synchro-scan shutter speed, refer to the table on the
1/100, 1/250, 1/500, 1/1 000, 1/2 000, 1/4 000,next page.
1/10000:Electronic shutter operates at one of these
speeds as selected.