Example:
A6AO.bin = AK4356, ASA, OLD VFD
C2FN.bin = CS4392 ,ASA, NEW small VFD
Service CD should contains following 16 files;
A6AO.binA6AN.binA6FO.binA6FN.binA6AT.bin A6FT.bin
P6AO.binP6AN.binP6FO.binP6FN.bin P6AT.bin P6FT.bin
A2AO.binA2AN.binA2FO.binA2FN.bin A2AT.bin A2FT.bin
C2AO.binC2AN.binC2FO.binC2FN.bin C2AT.bin C2FT.bin
Note: Update CD should have no volume ID.
12.4 CD UPTADE PROCEDURE:
1) Any Player can be updated automatically with Update CD which contains
proper files (see Service Cd.Jpg )
2) Burn up CD within proper files
2) There should be no Volume Name for CD
3) Open Tray and place update CD
4) You can see "Upgrade File Detected. Press Play to start" OSD message
5) Press Play button to start upgrade
6) You can see "File copying" OSD message for a few second
7) Tray is open automatically
8) No need for CD in tray;Take it from tray.
9) During upgrade procedure "CD upgrade start, Please wait.." indicator at
OSD, and "UPG" indicator at VFD
10) Upgrade procedure takes about a few minutes, please wait if tray is open.
11) When CD update is finished tray is closed, screen is refreshed, update is
finished.
12) To see Version Page;
- Press DISPLAY button from remote
- Press ?1?-?3?-?5?-?7? at Setup Menu
- Setup Menu screen refresh and ?Version? selection
can be seen under ?Preferences Setup?
- Select ?Version?or version Page
- 1st line contains release number like EFXX
th
- 5 line contains hardware options and build number
- Press ?DISPLAY? button on remote control to exit hidden menu.
12.5 Region Management
At version Page by using arrow keys you can change region.
13 |