Active carbon filter
" Operation
The activated charcoal filter is only fitted in
recirculation type hoods.It will retain odours until
it becomes saturated.It cannot be washed or
regenerated,and must be replaced when the In-
tensive Speed LED T5 starts to flash,or at least
once every 4 months of use.Attention:in
recirculation type hoods the T2 Motor LED may
start to flash as well as the Speed + T4 LED.This
indicates that as well as replacing the activated
charcoal filter,it is also necessary to perform
maintenance operations on the metal grease filters
(see paragraph Metal grease Filter).
" Replacing
Take off the metal grease filters (fig.11) and
remove the activated charcoal filter from its
housing by turning the clips provided (fig.12). FitFig. 12
the new activated charcoal filter and replace the
metal grease filters.
" Enabling the alarm signal
In recirculation type hoods the saturated filters alarm must be enabled as indicated below:
" Turn off the lights T1 and the Suction Motor T2;
" Press and hold the button T4 for at least 10 seconds,until the Leds start to flash.Note the
number of flashes:
" 2 flashes of the LED Activated charcoal filter saturation alarm ENABLED
" 1 flash of the LED Activated charcoal filter saturation alarm DISABLED
" Resetting the alarm signal
To turn the alarm signal off, proceed as follows:
" Press the button T4 for at least 3 seconds, until the Leds flash in confirmation. In any
case the saturated filters alarm will only come into operation when the suction motor is
turned on.
ATTENTION - There could be a possible fire hazard if the filters are not replaced
according to these instructions.