Electrical connections
Any electrical work required to install this hob
Permanent Connection
should be carried out by a qualified electrician or
In the case of a permanent connection, it is necessary
competent person, in accordance with the current
that you install a double pole switch between the hob
regulations.
and the electricity supply (mains), with a minimum gap
THIS APPLIANCE MUST BE EARTHED.
of 3 mm. between the switch contacts and of a type
The manufacturer declines any liability should these
suitable for the required load in compliance with the
safety measures not be observed.
current electric regulations.
This hob is designed to be connected to a 230-240V
The switch must not break the yellow and green earth
50Hz AC electrical supply.
cable at any point.
Before switching on, make sure the electricity supply
Ensure that the hob supply cord does not
voltage is the same as that indicated on the hob rating
come into contact with surfaces with
plate. The rating plate is located on the bottom of thetemperatures higher than 50 deg. C.
hob. A copy is attached on the back cover of this book.
The hob is supplied with a 3 core flexible supply cord
incorporating a 3amp plug fitted. In the event of having to
change the fuse, a 3amp ASTA approved (BS 1362) fuseSupply cable replacement
must be used.
The cable used to connect the hob to the electrical supply
Should the plug need to be replaced for any reason, themust comply to the specifications given below.
wires in the mains lead are coloured in accordance with
the following code:
Min. size Cable/flex Cable / flex typeFuse
Green and Yellow - Earth
2
0.75 mmH05 V2V2-F (T90) 3 A
Blue- Neutral
Brown- Live
? Connect the green and yellow (earth) wire to
)the terminal in the plug which is marked with
the letter 'E' or the earth symbol or coloured
green and yellow.
NOTE:
The earth wire should be about 2 cm. longer
than the live and neutral wires.
? Connect the blue (neutral) wire to the terminal
in the plug which is marked with the letter 'N'
or coloured black.
? Connect the brown (live) wire to the terminal in
the plug which is marked with the letter 'L' or
coloured red.
Upon completion there must be no cut, or stray strandsFO 0390
of wire present and the cord clamp must be secure over
the outer sheath.
A cut off plug inserted into a 13 amp socket is
a serious safety (shock) hazard. Ensure that
the cut off plug is disposed of safely.
10 |