Allgemeiner Teil / General SectionCUC 1828
5.4 Setting the Volume on a Per-Programme Basis7.3 Forced Settings in AV Mode (AV1�AV3)
Call up the "Sound settings" menu with the blue button.The volume canPress the "6" button to call up the "TV PROGRAMME CHART" menu
be set for each individual programme position with "Volume P X"via "DIALOG CENTER". Move the yellow bar to "AV", select the
(volume offset).desired AV level and activate with the blue button. The entries mean:
- station identX,PB ->forced PAL B/G
6. Picture Settings in the Dialog Center- station identX,SE ->forced SECAM L
6.1 Basic Adjustment- station identX,NM ->forced NTSC M
- station identX,N4 ->forced NTSC 4.43
Call up the "Picture settings" menu with the red button. Following the- station identX,PM ->forced PAL M 60Hz
user guide it is possible to select the options: "Personal", "During the- station identX,PN ->forced PAL N 50Hz
day", "In the evening" and "Soft". The "Personal" option allows to
change the contrast, picture sharpness, noise reduction and white- station identX,P6->forced PAL 60Hz
balance. The other options do not. Certain values are fixed in these
cases.8. Setting the Analog Values
Differences between these options and "Personal":The last entered analog values are stored automatically after about
- "During the day": arbitrary noise reduction and picture sharpness,10s or when changing to the AV positions or vice versa. When
maximum contrast and changed white balanceexceeding the minimum analog values (maximum value is 63) as
- "In the evening": arbitrary noise reduction and picture sharpness,specified in the table below, the optimum value is initialised when
reduced contrast and changed white balanceswitching the TV on or changing from RF �> AV.
- "Soft": noise reduction at mid-value, minimum picture sharpness,The terrestrial programmes and the 4 AV positions have separate
reduced contrast and arbitrary white balance.analog values (except for the volume level).
6.2 Picture SharpnessMinimum ValueOptimum Value
Call up the "Picture settings" menu with the red button and selectBrightness1032
"Picture sharpness".
With the buttons 3 4 it is possible to set the picture sharpness in fourColour contrast1028
steps for each individual programme.B/W contrast1057
Volume 821
6.3 Perfect ClearHeadphone volume1020
With the red button call up the "Picture settings" menu and select
"Perfect Clear".9. Audio/Video Connectors
With the 3 4 buttons this function can be switched on or off.
Assignment of the input and output signals to the AV sockets:
6.4 Noise Reduction- MegaLogic models and decoder to AV 1 socket.
With the red button call up the "Picture settings" menu and select
"Noise reduct.".- On selection of "Decoder yes - for SAT no", it is always the TV signal
which is fed out from the CCVS output of the AV 1 socket.
With the 3 4 buttons it is possible to select the settings "Off", "Auto",The signal that is fed to the screen is present on the other EURO-AV
and "weak".socket.
- If no decoder is connected no signal is fed out from the CCVS output
7. Settings via the Station Identof the AV1 socket on playback.
- On selection of SVHS and Hi8 the socket switches over to the Y/C
Settings entered in the station identification for individual programmeinput.
positions cause the TV set to switch to a forced operating mode; as a- If a voltage change is recognized (from 0V to 6/12V on pin 8 of the
result, the automatic evaluation function is inactive.
Scart socket, or 0/5V of the automatic sync evaluation of the Cinch
7.1 Maximum Programme Number (reversing point)socket) the TV is switched over to the respective external signal
Call up the "TV PROGRAMME CHART" menu via "DIALOG CENTER"source. Exception on decoder operation:
pressing the "6" button.If the decoder information is set on a programme position and a 6V
When entering the channel number "00" on any programme positionswitching voltage is recognized on pin 8, the TV switches over to
by pressing the "P/C" button and entering "00", programme selectiondecoder operation.
with the buttons 1 2 is limited to the numbers lower than this position. - The respectively selected AV socket supplies the CCVS signal to the
If the reversing point is L 10, only single-digit, L 100 only dual-digitother Euro-AV socket(s).
programme selection is possible.- With MegaLogic video recorders the standard (VHS, SVHS or Hi8)
7.2 Forced Settings in Programme Modeis signalled to the TV receiver.
Call up the "TV PROGRAMME CHART" menu via "DIALOG CENTER"12V = switching voltage at the Euro-AV socket contact 8.
using button "6" and activate the desired TV station with the blue button.1V�3V = UData switching voltage for changing to RGB operation
The forced operating modes for the individual programme positionscontact 16.
must be entered into the last 3 places of the station identification
beginning with a comma so that only one place "X" is left for the actualSocketInputOutputSwitching Signal
station identification.AV 1 blackRGB-12V+1V evaluation
Example:X,MOonly mono sound
CCVSCCVS12V
The correct setting of the station ident shows only the first place, the
switching information will not be displayed.SCVS (Y/C) CCVS (converted) 12V
Indication:XAV 2 orange RGB-12V+1V evaluation
Possible switch settings:CCVSCCVS12V
- station identX,AV ->VCR time constant and AFCSCVS (Y/C) CCVS (converted) 12V
- station identX,AF ->AFC active
- station identX,MO ->forced monoAV 3 Camera CCVS-5Vproduced
- station identX,2T->2-channel sound mono Bfrom sync
- station identX,PB ->forced PAL B/G
- station identX,SE ->forced SECAM LAV 4 VGA VGA - -
- station identX,NM ->forced NTSC M
- station identX,N4 ->forced NTSC 4.4
- station identX,PM ->forced PAL M 60Hz
- station identX,PN ->forced PAL N 50Hz
- station identX,P6->forced PAL 60Hz
The options X,AV / X,AF / X, MO / X,2T are not available in AV mode.
1 - 24GRUNDIG Service |