3 ANOTHER ELECTRIC COMPONENTS
t Cooling is impossible
CompressorCheck if current flows to
doesn't run.the followingCause.
components.
a. ThermistorPoor contacting.
b. Starting devicesShorted or broken.
c. OLPPoor contacting
or shorted.
d. Compressor coilCoil shorted.
Replace
e. Circuit PartsPoor contacting
or shorted.each component.
Running state ofCheck a starting
Low voltage.Raise the voltage.
Compressor is poor.voltage.
Check if current flowsPoor contactingReplace
to starting devices.and broken.each component.
Check current flowing
Shorted.
in sub-coil of
Compressor.
Check capacity of OLP.Lack of capacity.
The items describedCoil of motorReplace
above are normal.Compressor.the compressor.
t Cooling ability is poor
Fan motorCheck current flowing
doesn't run.Poor contacting.in SWITCH, DOOR.
Replace
each component.
Coil is shorted.Check current flowing in the
MOTOR[MECH], FAN.
Much frost are stickedCheck current flowingReplace
Shorted.
to the EVAPORATOR.of the followingeach component.
components.
Y THERMISTOR
Y FUSE, MELTING
Check current flowingReplace
of the followingthe Heater, Sheath
Defect oncomponents.
Heater, Cord-L
Y HEATER, SHEATHReplace
Y HEATER, CORD-Lthe Heater, Cord-L
- 13 - |