3-23-2
SERVICE TEST PROGRAMTo start service test program
hold " & AUX
depressed while
plugging in the mains cord
S refers to Service Mode
Display shows the
ROM version V refers to Version
"S-Vyy"
(Main menu)yy refers to Software version number of the uProcessor
(counting up from 01 to 99)
5DTC CONTROL &SERVICE PLAY MODEGAME PORT
MP3 CD MODULE(For non MP3 set only)TEST
CDNSTANDBY ONNGAMENTEST
(For MP3 set only)
Button pressed?Button pressed?Button pressed?
YYY
Note : Disc should be available on the tray before entering the Service Test Mode.
MESSAGESet is in Service PLAY ModeDisplay shows "GAME PORT"
STEPDISPLAYACTION
OKAYERROR
15DTC-Vnn-5DTC-ERVersion of the 5DTC control software (nn = Version Number).
CDN
MIX-ITN
Button pressed?
2MP3CD?02--Indicates the module used.Button pressed?
Y
** Choose**3TI-Vnn--Version of the MPEG software (nn = Version Number).Y
levelDisplay shows "5DTC-Vnn" -
by pressingVersion of 5DTC control software
**4TI BUSBUS OK BUS ER Communication test between the Main uP and CD Module(nn = Version Number).
QDTC works as in normal operation.STEPDISPLAYACTION
In case of failures, error(SCROLL ONCE)
**5TI SLD I--CD SLEDGE MOTOR is moved in.codes according to Table 3A and
Table 3B will be displayed.
Choose desired1MIX-CDSelect CD as background sound source. Press PLAY to play the track.
**6TI SLD O--CD SLEDGE MOTOR is moved out.background sourceThe Service Play Mode is intended
to detect and identify the failures2MIX-TUSelect TUNER as background sound source.by pressing button
in the CD Mode.
**7TI FOCFOC OK FOC ER FOCUS SERVO Test." MIX-IT "
R
In this mode the DTC works as in
3MIX-USBSelect PC-LINK (for set with PC-LINK) as background sound source.
normal operation. The electronics
Press PLAY to play the track.
Press 9 to exitwill still function even when an error
is detected so that repair activities
can be carried out.4MIX-AUXSelect AUX as background sound source.
5MIX-OFFNo mixing.
Disconnect mains cord to exit
Error codeError DescriptionError codeError Description
E1000Focus ErrorE1006Subcode Error
Triggered when the focus cannot be found within a certain time when starting up the CD, or if the focusTriggered when a new subcode was missing for a certain time during playing of CD.
is lost for more than a certain time during playing of CD.
E1007PLL Error
The Phase Lock Loop could not lock within a certain time.
E1001Radial Error
Triggered when the radial servo is off-track for a certain time during playing of CD.
E1008Turntable Motor Error
Generated when the CD could not reached 75% of speed during start-up within a certain time. Disc
E1002Sledge In Errormotor problem.
The sledge did not reach its inner position (inner-switch is still close) before approximately 6 seconds
have passed by. Inner-switch or sledge motor problem.
E1020Focus Search Error
The focus point has not been found within a certain time.
E1003Sledge Out Error
The sledge did not come out of its inner position (inner-switch is still open) before approximately 250msE1061The tray could not enter the inside position and is opening again. This can happen if the tray is blocked
have passed by. Inner-switch or sledge motor problem.such that it cannot go fully inside, or if the 5DTC control module is defective and never closes.
E1079The tray could not reach the outside position and is stopped at its blocked position. This can happen if
E1005Jump Error
the tray is blocked such that it cannot go fully outside, or if the 5DTC control module is defective and
Triggered in normal play when the jump destination could not be found within a certain time.
never opens.
Table 3ATable 3B
Mini 2003_FW-C/M 5xx/7xx_Service Test Program (dd wk0306) |