DEH-P930,P9300,P9350
(4) Display of Operational Status during Setup
Status No. ContentsProtective action
21Focus search startFocus search timeout.
22Focus search 2Focus search timeout.
23Focus search 3Focus search timeout.
24Focus search 4Focus search timeout.
25Focus search(Setup protection)Focus slips off.
26Focus search(Fast recovery)Focus slips off.
27RF detectionFocus slips off.
28Spindle rough servocontrolFocus slips off.
29Tracking balance adjustment startFocus slips off.
30Tracking balance adjustment 2Focus slips off.
31Tracking balance adjustment 3Focus slips off.
32Tracking close start(Spindle stationary servocontrol setting)Focus slips off.
33Tracking close 2Focus slips off.
34Tracking close 3Focus slips off.
35Focus/Tracking AGC startFocus slips off.
36Focus/Tracking AGC 2Focus slips off.
37Focus/Tracking AGC 3Focus slips off.
38Focus/Tracking AGC 4Focus slips off.
39Focus/Tracking AGC 5Focus slips off.
40Focus/Tracking AGC 6Focus slips off.
41Focus/Tracking AGC 7Focus slips off.
42Focus/Tracking AGC 8Focus slips off.
43FE bias startFocus slips off.
44FE bias 2Focus slips off.
45RF AGC startFocus slips off.
46RF AGC 2Focus slips off.
47Lock check startFocus slips off.
48Lock is being checkedFocus slips off.
49Subcode check startFocus slips off, spindle lock is not performed.
50Subcode is being checkedFocus slips off, no subcode can be read.
56 |