INSTALLING OPTIONAL UNITSNovember 29, 1999
11. Plug in the machine and turn on the main power switch.
12. Enter the service mode and set bit 2 of communication switch 16 to ?1?.
13. Exit the service mode and turn off the machine, then turn the machine back on.
14. Enter the service mode again, print the system parameter list and make sure
that ?G4? is listed as an option. Then exit the service mode.
15. Program the items required for ISDN communications.
Please refer to the ISDN option service manual for details.
Important:
Make sure that you input the following items when you connect the machine under
the US National ISDN network.
? SPID (Service Profile ID) Number: G4 SPID/ G3 SPID
? Subscriber number: G4 Subscriber Number (G4 Own Number)/ G3 Subscriber
Number (G3 Own Number)
NOTE: SPID is used when the machine is connected under the US National ISDN
network. If SPID is not used, or if the machine is not connected under the
US National ISDN network, turn it off with user parameter switch 06 bit 6.
End of Procedure
3-12 |