51GT-25S
Adjustment of Data within the NVM memory
To access the NVM memory, press the channel up button on the remote control until the NVM setting is
reached. Note that the NVM address is shown in green and the NVM value is shown in red.
Each of the NVM values are stored as a hexadecimal code, each code comprises of two hexadecimal
numbers. Each of these numbers will break down into bit four binary code as in the example below.
Hex code A 5
Binary code 1010 0101
Button on remote to toggle Bit 7654 3210
In the example given above, the hexadecimal code is A5, the binary equivalent is 1010 0101. The remote
control button to toggle each bit on or off (1 or a 0) is shown below the binary code. Therefore to change this
to A6, remote control buttons 1 then 0 would have to be pressed.
NVM LIST DESCRIPTION
PAGEADDRESSDESCRIPTIONVALUE
000RTEMP: TEMPERATURE RED15
01GTEMP: TEMPERATURE GREEN18
02BTEMP: TEMPERATURE BLUE0E
03VSHIFT: VERTICAL SHIFT22
04HSHIFT: HORIZONTAL SHIFT22
05VTAMP: VERTICAL AMPLITUDE0A
06VSLOPE: VERTICAL SLOPE12
07Y_DELAY: LUMA DELAY08
08Y_DELAY_S: LUMA DELAY SECAM08
09S_CORR: S-CORRECTION00
0AE_CAG : CAG ADJUSTEMENT VALUE0A
0BEA_OPT: TV OPTIONS70
0: FP: SYSTEM B/G (0)- B/G+L, MESSAGE RECHERCHE
1: AV FRONTAL: NOT INCLUDED(0), INCLUDED(1)
2: TUNING LOCK (HOTEL): LOCKED+SWITCH-ON PR1(1)
NO LOCKED (0)
3: UHF-ONLY: BAND UHF(1) ALL BANDS(0)
4: PAL ONLY(1), PAL+ SECAM(0)
5: CHILD LOCK: CHILD LOCK ACTIVE(1)
CHILD LOCK NO ACT(0)
6: AUTO FIRST: TUNING FIRST MENU: AUTO (1)
MANUAL (0)
7: ING_OSD: OSD_ENGLISH(1) OSD-SYMBOL(0)
0CEAFT: AFT ADJ FOR B/G & L SYSTEMS40
0DEAFT_: AFT ADJ FOR L' SYSTEMS1F
0EEVOLMAX: MAX. VOLUME LIMITFF
0FCHECKSUM: SIGNATUREA5
10RTEMP2: TEMPERATURE RED15
11GTEMP2: TEMPERATURE GREEN18
12BTEMP2: TEMPERATURE BLUE0E
13VSHIFT2: VERTICAL SHIFT22
14HSHIFT2: HORIZONTAL SHIFT22
15VTAMP2: VERTICAL AMPLITUDE0A
16VSLOPE2: VERTICAL SLOPE12
17Y_DELAY2: LUMA DELAY08
18Y_DELAY_S2: LUMA DELAY SECAM08
6 |