SERVICE MODE LIST
This unit provided with the following SERVICE MODES so you can repair, examine and adjust easily.
To enter the Service Mode, press both set key and remote control key for more than 2 seconds.
Set KeyRemocon KeyOperations
Reset the user setting items (PICTURE, VOLUME and LANGUAGE) to the initial state
VOL. (-) MIN0
for delivery.
Initialization of the factory.
NOTE: Do not use this for the normal servicing.
VOL. (-) MIN1
If you set a factory initialization, the memories are reset such as the
channel setting, and the POWER ON total hours.
POWER ON total hours is displayed on the screen.
Refer to the "CONFIRMATION OF HOURS USED".
VOL. (-) MIN6
Can be checked of the INITIAL DATA of MEMORY IC.
Refer to the "WHEN REPLACING EEPROM (MEMORY) IC".
Writing of EEPROM initial data.
VOL. (-) MIN8
NOTE: Do not use this for the normal servicing.
Display of the Adjustment MENU on the screen.
VOL. (-) MIN9
Refer to the "ELECTRICAL ADJUSTMENT" (On-Screen Display Adjustment).
CONFIRMATION OF HOURS USED
POWER ON total hours can be checked on the screen. Total hours are displayed in 16 system of notation.
NOTE: If you set a factory initialization, the total hoursADDRESS DATA
is reset to "0".
1.Set the VOLUME to minimum.
INIT 01 00Initial setting content of MEMORY IC.
2.Press both VOL. DOWN button on the set and ChannelCRT ON 0010POWER ON total hours.
button (6) on the remote control for more than 2 seconds. = (16 x 16 x 16 x thousands digit value)
3.After the confirmation of using hours, turn off the power. + (16 x 16 x hundreds digit value)
+ (16 x tens digit value)
FIG. 1 + (ones digit value)
WHEN REPLACING EEPROM (MEMORY) IC
If a service repair is undertaken where it has been required to change the MEMORY IC, the following steps should be taken to
ensure correct data settings while making reference to TABLE 1.
NOTE: No need the setting due to the adjustment value except the list below.
INI +0 +1+2+3+4+5+6+7+8 +9 +A +B +C +D +E +F
00 ---00381E173086400858 EF07839F0875
101000808080 3C60------9F---800042------
20 --- ---------C00002 208000181F00---C0 00
30 00--- ---7F07 0040 4454000050 0C 000000
Table 1
1.Enter DATA SET mode by setting VOLUME to minimum.
2.Press both VOL. DOWN button on the set and Channel button (6) on the remote control for more than 2 seconds.
ADDRESS and DATA should appear as FIG 1.
3.ADDRESS is now selected and should "blink". Using the VOL. +/- button on the remote, step through the ADDRESS until
required ADDRESS to be changed is reached.
4.Press OK to select DATA. When DATA is selected, it will "blink".
5.Again, step through the DATA using VOL. +/- button until required DATA value has been selected.
6.Pressing OK will take you back to ADDRESS for further selection if necessary.
7.Repeat steps 3 to 6 until all data has been checked.
8.When satisfied correct DATA has been entered, turn POWER off (return to STANDBY MODE) to finish DATA input.
After the data input, set to the initializing of shipping.
9.Turn POWER on.
10.Press both VOL. DOWN button on the set and Channel button (1) on the remote control for more than 2 seconds.
11.After the finishing of the initializing of shipping, the unit will turn off automatically.
The unit will now have the correct DATA for the new MEMORY IC.
C-1 |