Chassis E9-service manual
ADJUSTMENTADJUSTMENTADJUSTMENT ACTIVITY
CONDITIONAND RESULT OF SETTINGS
21. GREEN" To antenna connector of" With remote
COMPONENTTV set, which is switchedcontroller set value:
OF WHITEon and operates in service24: Pict. Tube Philips,
mode, connect VF signalPanasonic.
source with PHILIPS test28: Pict. Tube Thomson.
picture.
" Select the following serviceThis value is for
setting:orientation and depends
SERVICE PARAM: G VALUE: xxof picture tube.
22. BLUE" To antenna connector of" With remote
COMPONENTTV set, which is switchedcontroller set value:
OF WHITEon and operates in service24: Pict. Tube Philips,
mode, connect VF signalPanasonic.
source with PHILIPS test20: Pict. Tube Thomson.
picture.
" Select the following serviceThis value is for
setting:orientation and depends
SERVICE PARAM: B VALUE: xxof picture tube.
23. REFERENCEPAL /SECAM BG/L
OSCILLATING" With remote controller select the" With keys for set value changing set
CIRCUIT OFfollowing service setting:parameter value.
DEMODULATOR SERVICE PARAM: I1 VALUE: xxSERVICE PARAM: I1 VALUE:40
PAL /SECAM /L'
" With remote controller select the" With keys for set value changing set
following service setting:parameter value.
SERVICE PARAM: I2 VALUE: 00SERVICE PARAM: I2 VALUE: 00
PAL /SECAM /DK
" With remote controller select the" With keys for set value changing set
following service setting:parameter value.
SERVICE PARAM: I3 VALUE: 40SERVICE PARAM: I3 VALUE: 40
24. TIME DELAY OF" To antenna connector of TV set, which" With remote controller set such delay
LUMINANCEis switched on and operates in servicesetting that signals of colour and
SIGNALmode, connect VF signal source withblack - white picture overlap.
PHILIPS test picture.
" Select the following setting:
SERVICE PARAM: YD VALUE:xxRecommended value: D
25. MAX. VOLUME
FOR HOTEL TV
Setting is possible only for" Select the following setting:" With remote controller set desired
colour TV configured forSERVICE PARAM: HM VALUE: xxvalue of volume.
hotel TV.
26. OPTION BYTE 1" Select the following setting:" See option bytes.
SERVICE PARAM: O1 VALUE: xx
27. OPTION BYTE 2" Select the following setting:" See option bytes.
SERVICE PARAM: O2 VALUE: xx
28. OPTION BYTE 3" Select the following setting:" See option bytes.
SERVICE PARAM: O3 VALUE: xx
29. OPTION BYTE 4" Select the following setting:" See option bytes.
SERVICE PARAM: O4 VALUE: xx
17 |