InstallationInstallation
Water inletElectrical connection
Connect the
This machine is designed to operate on a 220-230 V, single-phase,
water inlet hose50 Hz supply.
to a separate tap
Check that your domestic electrical installation can take the maximum
with a 3/4"
load required (2.2 kW), also taking into account any other appliances in
thread after hav-A
use.
ing inserted the
Connect the machine to an earthed socket.
small filter OA�
supplied with theThe manufacturer does not accept any responsibility for damage or
machine.injury through failure to comply with the above safety precaution.
The other end of the inlet hose which connects to the machine can be
turned in any direction. Simply loosen the fitting, rotate the hose andPermanent connection
retighten the fitting, making sure there are no water leaks.
In the case of a permanent connection it is necessary that you install a
The inlet hose must not be lengthened. If it is too short and you do notdouble pole switch between the appliance and the electricity supply
wish to move the tap, you will have to purchase a new, longer hose spe-(mains), with a minimum gap of 3 mm between the switch contacts and
cially designed for this type of use.of a type suitable for the required load in compliance with the current
electrical regulations.
Water drainageThe switch must not break the yellow and green earth cable at any
The end of the drain hose can be positionedpoint.
in three ways:
This operation must be performed by a qualified electrician.
Hooked over the edge of a sink using the
plastic hose guide supplied with the
machine. In this case, make sure the end
cannot come unhooked when the machine
is emptying.
This could be done by tying it to the tap
with a piece of string or attaching it to the
wall.
In a sink drain pipe branch. This branch must be above the trap so that
the bend is at least 60 cm above the ground.
Directly into a
drain pipe at a
height of not less
than 60 cm and
not more than
90 cm.
The end of the
drain hose must always be ventilated, i.e. the inside diameter of the
drain pipe must be larger than the outside diameter of the drain hose.
The drain hose must not be kinked. Run it along the floor; only the part
near the drainage point must be raised.
4849 |