ELECTRICAL CONNECTIONS
Any electrical work required to installIf the supply cord is damaged, it must
this hob and the supply cable should bebe replaced by the manufacturer or its
carried out by a qualified electrician orservice agent or a similarly qualified person
competent person, in accordance with thein order to avoid a hazard.
current regulations.
After installation and connecting, the
cable must be placed so that it cannot at any
THIS COOKER MUST BE EARTHED.
point reach a temperature of more than 50°C
above the ambient temperature.
The manufacturer disclaims any
responsibility should these safety
instructions not be carried out.
This cooker is designed to be connected to a
230/400V, 50Hz electrical supply.
To connect to the electricity supply, use cable
supply
type H05 RR-F.
cable
Before switching on, make sure the electricity
supply voltage is the same as that indicated on
the rating plate.
The cooker is supplied without supply cable. ABefore connecting check that:
flexible supply cable must be fitted, in" fuse and household electric installation can
accordance with the specification gived in thebear the charge of the appliance (see rating
relevant table no. 1.plate);
" The socket or the omnipolar switch used for
In case of a direct connection to the mains you
connection is easily reachable when the
have to interpose an omnipolar switch a
appliance is installed.
minimum opening between contacts of 3 mm.
How to proceed?
The switch should be sited within 2m of the hob
" Unscrew and remove the protective cover at
and be easily accessible upon completion of the
the back of the appliance;
installation.
" Connect the power cord to the terminal of the
cooker according to the table no.1;
The yellow-green grounding cable has not to be
" Fix by means of cable clamp;
interrupted by the switch.
" Make sure that the connection to the terminal
NOTE: The earth wire should be about 2 cmis matching the network power;
longer than the live and neutral wires." Remount and screw the protective cover at the
back of the appliance.
Table no. 1
Rated voltage230V 1N, 230/400V 3N, 230V 3~, 230/400V 2N
Tri-phase Y 3 ph.Bi-phase Y 2 ph. +
Connection typeSingle phaseTri-phase
+ neutralneutral
1 2 3 4 51 2 34 51 2 3 4 51 2 3 4 5
Cable connection to the
terminal plate
L1NPEL1 L2 L3 NPEL1L2L3PEL1 L2NPE
Network voltage1N/230 V3N/400 V3/230 V2N/400 V
Voltage of heating
230 V230 V230 V230 V
elements
Fusible capacity20 A3 x 10 A3 x 20 A2 x 10 A
2222
Cable section3 x 4 mm5 x 2,5 mm4 x 4 mm4 x 2,5 mm
5 |