TTRROOUUBBLLEESSHHOOOOTTIINNGG ((ccoonnttiinnuueedd))
Indicators Message
The POWER indicator, LAMP indicator, and TEMP indicator are lit and blank as follows. Take the
appropriate measures.
Table 9. Indicators Message
POWERLAMPTEMP
Contents
indicatorindicatorindicator
Lights
Turns off Turns off The Standby mode has been set.
orange
Blinks
Turns off Turns off Warming up. Please wait.
green
Lights
Turns off Turns off ON. Normal operation possible.
green
Blinks
Turns off Turns off Cooling. Please wait.
orange
Lamp is not lit.
The interior of the equipment may be too hot. Switch
LightsLights
Turns offpower OFF, wait 20 minutes until the equipment cools,
redred
and Switch power ON again. Replace the lamp if the
same problem occurs.
No lamp or lamp cover is found, or hasnOt been fitted in
correctly.
LightsBlinksSwitch power OFF, and wait for 45 minutes until the
Turns off
redredequipment cools. Check fitting of the lamp and lamp
cover, and switch power ON again. Contact your dealer if
the same problem occurs again.
The cooling fan is not operating.
Switch power OFF, and wait for 20 minutes until the
LightsBlinks
Turns offequipment cools. Check for foreign matters in the fan,
redred
and switch power ON again. Contact your dealer if the
same problem occurs again.
The interior of the equipment is too hot. *1)
Switch power OFF, and wait for 20 minutes until the
equipment cools. Check whether the ventilation openings
LightsLights
Turns offare blocked, whether the air filter is dirty, or whether the
redred
ambient temperature exceeds 35 !C. Then switch power
ON again. Contact your dealer if the same problem
occurs again.
*1) When the internal temperature becomes excessive power is switched OFF
automatically for safety reasons, and the indicator is extinguished. Set the power switch to
[O] and wait for 20 minutes until the equipment has cooled sufficiently.