RECORDING� Setting time codes �
Top MENU1.Display the top MENU.
���MENU���
SYSTEM. .Remote controllerMain unit
REMOTE . .
AUD I O / V I DEO . .Press the MENU button.Press the EJECT and STOP
TIME CODE . .buttons simultaneously while
DI SPLAY SET . .
CLOCK ADJUST . .no cassette is loaded.
FACTORY SETTI NG CANCEL2.Display the TIME CODE menu.
DRUM HOUR METER 000000H
EX I T
Remote controllerMain unit
Select the TIME CODE itemSelect the TIME CODE item
with the PLAY/STOP button
TIME CODE menuwith the / button and
press the SET or button.and press the PAUSE or FF
MinuteFrame
Time CodeHour Secondbutton.
3.Preset the time code (hour, minute, second and frame).
���T IME CODE���
TC00:00:00:00
CLEARCANCELRemote controllerMain unit
NDF / DF ( NTSC )DROP
DV TC DUP .OFF1Select the TC item with the1Select the TIME CODE item
TC OUT OFFSETOFF/ button and press thewith the PLAY/STOP button
PAGE BACK
SET or button.and press the PAUSE or FF
button.
Y The hour digits blink.
Press the / button to2Press the FF or REW but-2
ton to shift to the next digit
shift to the next digit seg-
Framing mode segment.
(NTSC only)ment.
3Press the PLAY/STOP but-3Press the / button to
ton to change the value of
change the value of the
Resetting the time codethe blinking digits.blinking digits.
to zero:Repeat steps and 4Repeat 2 and 3 steps
423
above and set all the values.
1Select the CLEAR menuabove and set all the val-
Press the PAUSE button.
ues. Press the SET button.
item.
2Set the value to EXECUTE
4.Set the framing mode (NON DROP / DROP) ... (NTSC only)
and press the SET button
(remote controller) or theRemote controllerMain unit
PAUSE button (Main unit).
1Select the NDF/DF item1Select the NDF/DF item with
with the / button andthe PLAY/STOP button and
Memo
press the SET or button.press the SET or FF button.
Framing mode (NTSC only)
2Press the / button to2Press the PLAY/STOP but-
DROPselect the value.ton to select the value.
:Time codes that match3Press the SET button to3Press the PAUSE button to
the actual time.confirm the setting value.confirm the setting.
NON DROP
5.Return to the usual screen.
:Use this setting if the
number of frames isRemote controllerMain unit
important.
Press the MENU button.Press the EJECT button.
Recording time codes of a DV input terminal:
Y Set the DV TC DUP. item of the TIME CODE menu to ON.
Y When the DV TC DUP. item is set to ON, the time code and user-bits form the DV terminal are
recorded.
Memo
If the REC button is held down in the STOP mode when the DV TC DUP. item is set to ON, the EE signals of the
time codes from the DV input terminal can be checked.
E-36
DV2500P_p33-40362/27/03, 8:01 PM |