Menu Screens
MENU SCREEN 2
The time/date display position, monitor screen blue display and buzzer settings are performed on Menu Screen 2.
5Display position selectionTo release the buzzer:
This selects the position where the date and time ALARM: Release alarm recording.
are to be displayed on the TV monitor.TAPE END: Transfer the mode from the tape end or
(L-UPPER ? R-UPPER ? L-BOTTOM ? press the STOP button.
R-BOTTOM ? CENTRE ? OFF ? L-UPPER...)TAPE REMAIN: Transfer the mode (but not to
PAUSE or REC REVIEW) from the recording mode
6Blue displayor press the REC button.
This sets a blue display on the monitor screen at all ERR WARN: Release the warning status.
times except while recording or playback is in progress.
BLUE: The display on the monitor screen is blue at Y When TAPE END or TAPE REMAIN has been set
all times except while recording or playback is in to OFF, the buzzer will not sound; however, the
progress.REMAIN display will remain lit or flashing.
CAMERA: The pictures from the video input Y When TAPE END or TAPE REMAIN has been set
connector are shown on the monitor screen at all to ON, REMAIN lights or flashes on the display
times except while playback is in progress.tube at the same time as the buzzer sounds.
They cease flashing when the buzzer is released.
7Setting of the buzzer sound
ALARM: The buzzer sounds once alarm recording is Note:
performed.The remaining tape is displayed only with NV-E120
TAPE END: When the tape end is reached in the and NV-E180 tapes. It is not displayed when any
recording mode, the buzzer sounds while the tape is other tapes are used.
at the end.
TAPE REMAIN: The buzzer sounds when there is
only about 3% (with an NV-E180 tape) of the tape
remaining before the end is reached in the recording
mode.
ERR WARN: The buzzer sounds when the unit is set
to the warning status.
MENU SCREEN 3
The alarm recording mode and terminal output are set on Menu Screen 3.
8Setting of alarm recording and recording time 0Alarm recall (see page 20)
mode during alarm recording (see page 19)This checks the time when an alarm signal was
When there is an alarm input during recording in input (up to 4 times).
the time lapse mode, the recording time mode is
switched to the designated mode (3H/6H), and the qTerminal connector output signal setting
details of the alarm status are faithfully recorded.ERR WARN: When trouble has occurred in the unit
(AUTO OFF), the LOW signal is output.
9Alarm recording duration settingREC: The LOW signal is output during recording.
This sets the time allowed to elapse from the start
of alarm recording until its end. This time can be
set individually from 30 sec. to 10 min.
(30 SEC ? 1 MIN ? 2 MIN ? 3 MIN ? 5 MIN ?
10 MIN ? CONTINUE ? MANUAL)
CONTINUE: Alarm recording continues until the
tape end.
MANUAL: Alarm recording is performed while the
alarm input continues.
10 |