16ENGLISH
� If you prefer to replace the lamps yourself, proceed as follows:
1First remove the mains plug from the wall socket.
C2Loosen the screws and remove the two end caps.
C3Pull out the protective shield completely.
After this, the lamps and starters are accessible.
4Rotate the lamps slightly to the left or to the right.
5When unlocked remove them from the lamp holders.
6Remove the starters by turning slightly to the left and
withdrawing.
(Half the amount of starters are at each end of the Combi solarium.)
7To place new lamps and starters proceed in reverse order and
direction.
8Slide the protective shield back into the profile.
HB558 only:The lamp of the facial tanner may only be replaced by
authorised Philips Service personnel.
Do not forget to fix the end caps by means of the screws.
The tube lamps of solariums contain substances which may pollute the
environment.When discarding old tube lamps, please ensure that they
are separated from the normal household refuse and that they are
disposed of at an officially assigned place.
Information & service
If you need information or if you have a problem, please visit the Philips
Web site at www.philips.com or contact the Philips Customer Care
Centre in your country (you will find its phone number in the
worldwide guarantee leaflet). If there is no Customer Care Centre in
your country, turn to your local Philips dealer or contact the Service
Department of Philips Domestic Appliances and Personal Care BV. |