Complete Installation
NOTE: Handle the air conditioner gently. Position the ground wire pointing straight up. Put the excess
ground wire between the coil and the air conditioner cabinet.
1. Make sure the free end of the ground wire is outside of the
cabinet.
A
WARNING
Excessive Weight Hazard
++
Use two or more people to move and install
air conditioner.
+
Failure to do so can result in back or other injury.B
A.Green ground wire
2. Insert the air conditioner into the cabinet. B.Ground screw
NOTE: Make sure the free end of the ground wire is outside
4. Insert the front tabs of the front panel into the top of the
of the cabinet.
cabinet and swing the front into place.
5. Attach the bottom front of the panel with the front panel
screws. Replace the control knobs (on some models).
NOTE: For through-the-wall installations, if needed, install
molding around the room side of the cabinet.
A
WARNING
A.Ground wire outside of the cabinet
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Electrical Shock Hazard
Do not use an extension cord.
Connect green ground wire to ground screw.
Failure to follow these instructions can result in death,
Failure to do so can result in death or electrical shock.fire, or electrical shock.
3. Connect the green ground wire to the ground screw. 6. Plug into a grounded 3 prong outlet.
7. Press RESET on the power supply cord. See ?Electrical
Requirements.?
10 |