Window Installation Electrical Requirements
Window opening measurements:
27" min. to 40" max. (68.6 cm to 101.6 cm) opening width.WARNING
19" min. (48.3 cm) opening height.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
A
Do not use an adapter.
B
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
A.27" min. to 40" max. (68.6 cm to 101.6 cm)
B.19" min. (48.3 cm) The electrical ratings for your air conditioner are listed on the
model and serial number label. The model and serial number
label is located on the right-hand side of the cabinet.
Through-the-Wall InstallationSpecific electrical requirements are listed in the chart below.
Follow the requirements for the type of plug on the power supply
The wall opening measurements should be:cord.
Height: 18" (45.7 cm) plus twice the thickness of wood used
to build frame.Power supply
Width: 26" (66 cm) plus twice the thickness of wood used to cord Wiring requirements
build frame.
115-volt (103.5 min. - 126.5 max.)
Depth: 2" (5 cm) minimum to 8" (20.3 cm) maximum.
0-12 amps
15-amp time-delay fuse or circuit breaker
CUse on single outlet circuit only.
A
230-volt (207 min. - 253 max.)
B(0.6 cm)0-12 amps1D?"
D15-amp time-delay fuse or circuit breaker
Use on single outlet circuit only.
C
A.18" (45.7 cm)C.Wood thickness
B.26" (66 cm)D.2" (5 cm) minimum to 8"(20.3 cm) maximumRecommended grounding method
This air conditioner must be grounded. This air conditioner is
equipped with a power supply cord having a grounded 3 prong
plug. To minimize possible shock hazard, the cord must be
plugged into a mating, grounded 3 prong outlet, grounded in
accordance with all local codes and ordinances. If a mating outlet
is not available, it is the customer's responsibility to have a
properly grounded 3 prong outlet installed by a qualified electrical
installer.
It is the customer's responsibility:
To contact a qualified electrical installer.
To assure that the electrical installation is adequate and in
conformance with National Electrical Code, ANSI/NFPA 70 -
latest edition, and all local codes and ordinances.