CONVERGENCE ADJUSTMENT
EXPLANATION OF KEY-FUNCTION IN THE CONVER-
1.Receive NTSC signal.GENCE ADJUSTMENT MODE
2.Enter to the service mode. (See Page 10.)
Load BACK UP DATA:1 button
Up :2 button
RCUTSelet Green color:3 button
40HLeft :4 button
Blinking of cursor ON/OFF:5 button
Right:6 button
Adjust mode ON/OFF:7 button
GENERAL ADJUSTMENTSDown:8 button
Vertical stripe ON/OFF9 button
Erase Green line:0 button
3.Press "7" button to enter the convergence adjusting mode,Erase Red line:100 button
and the internal net pattern will be displayed. Then, pressErase Blue line:ENT button
"9" button to display veritcal stripes.
4.Select the point and the color by pressing following but-
tons. (Cursor should be blinking.)
"2", "8", "4", "6" : To select point
"3" : To select color
5.Then press "5" button, and adjust the convergence by
pressing following buttons. (Cursor should not be
blingking.)
"2", "8", "4", "6" : To adjust convergence
"3" : To select color
SPECIFIC INFORMATIONS6.Repeat from steps 3 to 4 until the convergence and the
geometry become fine. (See Page 14.)
7.Press "7" button to momorize the adjusted data.
8.Message of "PLEASE PUSH TOUCH FOCUS" will be dis-
played, and press TOUCH FOCUS button which is located
on the front panel.
9.TOUCH FOCUS CALIBRATION will start.
10.Soon message of "CALIBRATION FINISHED" will be dis-
played, and then a normal picture will be displayed.
11.Then push TOUCH FOCUS button again, and confirm that
the convergence does not change.
Note: If message of "TOUCH FOCUS ERROR" is displayed,
1) Check the connection between four sensors and
Convergence Unit.
2) Check the geometry of internal net pattern. (See Page
14.)
If any problem cannnot be found, hardware might have
problem.