Turn the control clockwise to select a higherY To switch the timer off:
temperature setting or anti-clockwise for a lower- Slowly turn the timer
9
temperature setting.control anti-clockwise
You can adjust the thermostat during use.and select setting I
10
(�Click!O) (fig. 9), or:
To find the ideal thermostat setting:20- Set the selector switch
- First set the thermostat control to maximum60to position O. In this
position by turning it clockwise until it will not go30case, the timer will keep
50
any further.40running but the
- As soon as you find the temperature in the roomappliance has been
agreeable, slowly turn the thermostat control anti-switched off.
clockwise to the point where the heater switches
off.
Pilot light
Please note that when you use the cool air setting
>, the thermostat control must be set to- When the appliance is connected to the mains and
maximum position.switched on by selecting setting >, 1 or 2 the
pilot light (F) will go on.
y = OFrost-free� position. This position- The pilot light will stay on until the appliance is
corresponds with the minimum thermostatswitched off by setting the selector switch (C) to
setting (i.e. approx. +5 !C / +41 !F) and can beposition O or by disconnecting from the mains.
used to keep the immediate vicinity of the- To indicate that the heater is still connected and in
heater free from frost. To prevent a pipe fromOswitched-on� position (>, 1 or 2), the pilot
freezing, for example, place the heater close tolight will stay on when the set temperature has
the pipe and select this setting.been reached and the thermostat has switched the
appliance off.
For the same reason the pilot light will stay on
Switching the appliance on/off manually when the safety cut-out switches the appliance off
(HD 3522 only)in case of overheating.
- The pilot light will go out when the timer switches
To switch the appliance on and off manually, set thethe appliance off with the selector switch in
timer (I) to position I. You can then switch theposition >, 1 or 2.
appliance on and off by means of the selector switch
(C).
Overheating safety device
Switching the appliance on/off by means of theTo prevent damage and risks due to overheating, the
timer (type HD 3522 only)built-in overheating safety device cuts off the power
as soon as the heating elements become too hot.
Type HD 3522 has been equipped with a timer (I).If this should happen:
When the timer is used, the appliance will switch- First check if it was not the thermostat that
itself off after a preset time (max. 60 minutes).switched the heater off by setting the thermostat
control to maximum position. If the heater does
Y To set the timer: not switch on again, the safety cut-out has been
- Turn the timer controlactivated.
8clockwise and set the- Remove the mains plug from the wall socket.
number of minutes (fig.- Let the heater cool down for 30 minutes.
8). The pilot light goes- Check whether you have placed the heater10
20on and the appliancecorrectly.
60switches on at the preset- Check whether something is obstructing the air
30temperature and settingflow. If necessary, clean the grilles with a vacuum
50
40(>, 1 or 2). Thecleaner.
appliance switches off- Put the plug back into the wall socket and switch
and the pilot light goesthe heater on again.
out as soon as the preset
time has elapsed. If the safety cut-out switches the heater off again:
- Remove the mains plug from the wall socket.
6 |