Electrical connectionsConnecting cable
Connecting the appliance to the electricityUseaH05 R-RF- typecablewithaminimum cro-ss-
22
supply must be carried out by qualifiedsection of 2.5 mmor 2.5 mmPVC twin and earth
professionals onl.y The oven must becable .
earthed in accordance with current
The cable should be connected according to
regulations
recommendations and the securing screws should be
(Earth = yellow and green).
tight. The protective conduction (Earth cable) should
be longer than the wires carrying the current. The
Fuse capacity : 13 Ampspower cable should be held firmly in place by the cable
clamp.
Whatever method of connection is employed, the
Before connecting the oven, check that :
appliance must be earthed in accordance with current
?the electrical wiring is in good condition,regulations.
?the fuses and the domestic power supply are ofIf the oven is to be connected to an existing cooker
sufficient capacity to support the oven (see ratingcontrol unit, it will be necessary to down rate the
plate),protective fuse to 15 amp.
?the plug or double pole switch used to connect the
oven is accessible once the appliance is installed.
Fixed connection :
In the event of a fixed connection, it is necessary that
you install a double pole switch between the appliance
and the electricity supply (mains), with a minimum gap
of 3 mm between the switch contacts and of a type sui-
table for the required load in compliance with the cur-
rent rules.
The switch must not break the yellow and green earth
cable at any point.
Fitting a plug :
If a plug is fitted, the wires in the mains lead are colou-
red in accordance with the following code :
green and yellow : Earth
blue...........: Neutral
brown.......... : Live
?The wire coloured green and yellow must be
connected to the terminal marked with the letter
Ť E Ž or by the earth symbol or coloured green and
yellow,
?The wire coloured blue must be connected to the
terminal ŤN Ž or coloured black,
?The wire coloured brown must be connected to the
terminal marked ŤL Ž or coloured red,
?Upon completion there must no cut or stray
strands of wire present and the cord clamp must
be secure over the outer sheath.