INSTALLATION
How to Install the Unit
1. To prevent vibration and noise, make sure
the unit is installed securely and firmly
2. Install the unit where the sunlight does notFence
shine directly on the unit.Awning
3. The outside of the cabinet must extendCooled air
Heat
outward for at least 28cm (11") and thereradiation
should be no obstacles, such as a fence or
wall, within 50.8cm (20") from the back of
the cabinet because it will prevent heat
About 12.7mm (1/2")
76.2cm (30")~
radiation of the condenser.
152.4cm (60")Over 50.8cm (20")
Restriction of outside air will greatly reduce
the cooling efficiency of the air conditioner.
CAUTION : All side louvers of the cabinet must remain exposed to the outside of the
structure.
4. Install the unit a little slanted so the back is slightly lower than the front
1
(about 12.7mm (/2")).
This will force condensed water to flow to the outside.
5. Install the unit with the bottom about 76.2cm (30")~152.4cm (60") above the floor level.
FeaturesandInstallation
Window Requirements
NOTE: All supporting parts should be secured to firm wood, masonry, or metal.
This unit is designed for installation in
55.8cm (22") to
standard double hung windows with actual91.44cm (36")
opening widths from 55.88cm (22") to38cm (15") minStool
(With frame curtain)
91.44cm (36").Offset
1
12.7mm (/2") to
The top and bottom window sash must open
1
31.8mm (1/4")
sufficiently to allow a clear vertical opening of
Sill
38cm (15") from the bottom of the upper sash
to the window stool.ExteriorInterior wall
1
47cm (18/2") min.
(Without frame curtain)
11 |