Special accessories
Active carbon filter
When the hood is used in recirculation mode an
active carbon filter should be used.
Order by the retailer
PNC 955 101 117
Installation
Unpacking
Check that the cooker hood has no damages.
Min
Transportation damages should immediately beMin
75 cm
reported to the one responsible for the transport65 cm
Damages, faults and eventually missing details
should immediately be reported to the seller.
Take care of the packing material so that small
Fig. 3
children cannot play with it.
Placement
The hood is to be mounted in a wall cupboard.
When installed, the hood must be not less than 65
cm. above electric burners or 75 cm. above gas or
mixed-fuel burners. (Fig. 3).
Electrical connection
Fig. 4
The hood has a power cord with moulded plugCC
with earth connection to be connected to a wallCC
outlet of 230 V.
The power cord length is 1,25 m.
Mounting under wall cabinetFF
FF
l Drill holes on the bottom of the cupboard as
shown in the supplied drilling diagram (Fig. 4),
do not consider the thickness of the front panel
of the cupboard.Fig. 5
l From inside the cupboard, insert the four 4.2x35
screws C (Fig.5) supplied with the unit and
screw them onto nuts F (Fig.5).
l By means of the appropriate screws, fit the
angle iron E (Fig.6) so that it is tightly fixed to
the wall.
l Make an hole on the top of the cupboard for the
E
passage of the discharge (see the drilling
diagram for diameter).Fig. 6
5 |