Instructions for the installer
The instructions given below are3 cm. longer than the other cables. The
designed specifically for a qualifiedsupply cable must in all cases be laid out in
installer and should aid him or her tosuch a way as to ensure that it does not
perform all installation, adjustment,reach at any given point a temperature 50°C
and maintenance operations withhigher than the ambient temperature.
absolute precision and in complianceSuitable power supply cables are the
with all current legislation andfollowing types, considering the respective
regulations. We strongly recommendnecessary section of cable: H07 RN-F, H05
that all operations for the installationRN-F, H05 RR-F, H05 VV-F, H05 V2V2-F
of your cooker be carryed out by(T90), H05 BB-F.
Qualified Personnel in accordance
with existing rules and regulations.Terminal block
The oven has an easily accessible terminal
Electrical connectionblock, which is meant to work with an
Prior to making the electrical connection,electric single-phase rate of 230 V (Fig. 7).
make sure that:
? the protection fuse and the domesticThe Manufacturer disclaims any liability
wiring system are suitable to carry thein case these accident-preventing rules
total electric load of the oven (see ratingare not observed.
plate);
? your domestic wiring system has an
efficient earth connection in compliance
with rules and laws in force;
? the wall socket or the omnipole switch
used for the electrical connection can
easily be reached after the oven is built
in.
This appliance is delivered without an
electric supply cable, therefore, you will have
to fit to it a supply cable with standard plug,
suitable for the total electric load shown on
the rating plate. The plug is to be inserted
into a suitable wall socket. If you require a
direct connection to the electric networkFig. 7FO 2159
(mains), it will be necessary to fit between
the appliance and the mains an omnipole
switch, with a minimum gap between
contacts of 3 mm, suitable for the required
load and in compliance with rules in force.
The green & yellow ground wire must not be
interrupted by the switch and it should be 2-
51 |