INTRODUCTION
WARNING: THIS APPLIANCE MUST BE EARTHED
RATING PLATEThe cable must be routed away from potentially hot
areas marked by X in the diagram below.
Record the model, product and serial numbers on the
back cover of this instruction book from the rating
plate. This is situated on the lower front frame of the
appliance and can be seen upon opening the fan
oven door.
REAR VIEW
To move the appliance, open the fan oven door, and
lift the appliance by holding inside the top of the
The appliance must be protected by a suitably rated
compartment.
fuse or circuit breaker. The rating of the appliance is
given on the rating plate.
Do not remove the rating plate from the appliance
as this may invalidate the guarantee.
INSTALLATION
If your appliance has been damaged in transit,
contact your supplier immediDOatelyNOT. attemptThis is a type Y appliance which means it is free-
to install it.standing and can be fitted with cabinets on one or
both sides. It may also be fitted in a corner setting.
Your appliance left the factory fully packaged toEnsure that the appliance is standing level.
protect it from damage. If it is delivered without
packaging anddamagehasoccurred,the
Side walls which are above hob level should be
manufacturer cannot accept responsibility. Contactprotected by heat resistant non-combustible material
you supplier for advice.
and MUST NOT be nearer than 40mm to the hob
side.
Once the packaging has been removed the appliance
should only be moved by hanDOd.NOT use a sackA nominal air gap of 2mm all around the appliance is
barrow or any other aid to lift the appliance as
required to enable the appliance to be moved into
damage may occur.
position.
Connection to the electricity supply must be carried
Two spacers have been incorporated into the back of
out by a qualified electrician/competent person.
the appliance to ensure hotplate level. Tiles or other
forms of deep wall covering should not obscure this
The electrical connection should be made using agap.
double pole isolating switch (cooker socket) with at
least 3mm contact separation in all poles. The cable
must have conductors of sufficiently high cross-
sectional areatopreventoverheatingand
deterioration.
2Air gap
Sixsquaremillimetres(6.)i00mmsthe
recommended cross-section area.
7 |